Non‐Surgical, In‐Stent Membrane Bioelectronics for Long‐Term Intracranial Pressure Monitoring
Traditional intracranial pressure (ICP) monitoring methods, using intraventricular catheters, face significant limitations, including high invasiveness, discrete data, calibration complexities, and drift issues, which hinder long-term and stable monitoring. Here, a non-surgical, in-stent membrane bioelectronic system is presented for continuous and reliable ICP monitoring. This platform integrates a capacitive thin-film sensor with a stent, enabling precise real-time detection of pressure fluctuations directly within the dural venous sinus without requiring skull penetration or frequent recalibration. The sensor demonstrates a high sensitivity of 0.052%/mmHg and a broad, readable pressure range of 3-30 mmHg while maintaining calibration-free and drift-free performance. A series of in vivo studies highlight the system's superior sensitivity, rapid sampling rate, and long-term stability compared to conventional microcatheters. Statistical analyses reveal a strong agreement between the device and clinical reference, underscoring its potential to revolutionize ICP monitoring. These advancements pave the way for broader clinical applications, minimizing complications and improving patient outcomes in neurocritical care.
Authors
- Mi Hyeon Kim (ORCID: https://orcid.org/0000-0002-9232-0401)
- Hodam Kim
- Yun Hyeok Choi (ORCID: https://orcid.org/0000-0002-5064-2226)
- Robert Herbert (ORCID: https://orcid.org/0000-0001-9885-0684)
- Woon‐Hong Yeo (ORCID: https://orcid.org/0000-0002-5526-3882)
- Deok Hee Lee (ORCID: https://orcid.org/0000-0003-0355-0449)
- Bruno Rigo (ORCID: https://orcid.org/0000-0002-1068-515X)
- Jaeho Lee (ORCID: https://orcid.org/0009-0008-3178-8730)
- Jimin Lee (ORCID: https://orcid.org/0000-0002-8703-0979)
- Allison Bateman
Institutions
- Ulsan College (KR)
- Louisiana State University (US)
- Georgia Institute of Technology (US)
- Asan Medical Center (KR)
- The Wallace H. Coulter Department of Biomedical Engineering (US)
- University of Ulsan (KR)
- Inje University Haeundae Paik Hospital (KR)
- Icahn School of Medicine at Mount Sinai (US)
Publication Details
- Journal
- Advanced Healthcare Materials
- Published
- 2025-02-16
- DOI
- https://doi.org/10.1002/adhm.202404680
- Citations
- 1
- Primary Topic
- Cerebrospinal fluid and hydrocephalus
- Type
- article
- Field-Weighted Citation Impact
- 0.91
Funders
- National Science Foundation
- Division of Electrical, Communications and Cyber Systems