Immersion cooling performance of nanofluid in a cylindrical cell battery pack using two-phase numerical simulations for varying discharge rates: A comparative study

• Nanofluid with Al2O3 nanoparticles for varying volume fractions (0.1% and 0.4%) using two-phase model. • A maximum reduction of 15 K in the maximum temperature compared to air. • A maximum reduction of 7 K in the maximum temperature compared to de-ionized water. • A temperature homogeneity of 5 K even for a higher discharge rate (5.8 C). Immersion cooling is gaining attention as it does not involve complex flow channels within the battery, making it easier to manufacture a compact battery thermal management system (BTMS) for high-discharge cells that could limit the operation of the battery pack within the optimal temperature range. Initially, forced air cooling performance is studied for various cell arrangements, such as aligned, staggered, and diamond, to arrive at the optimal cylindrical cell battery pack arrangement. The staggered configuration provided the best overall performance with a reduction in maximum temperature and enhancement in Nusselt number of 3.6 and 20 %, respectively, for an increase in pumping power of 25 % at higher discharge rates than aligned. Further, the cooling performance of air is compared to de-ionized water and its nanofluid with Al 2 O 3 nanoparticles for varying volume fractions (0.1% and 0.4%) and discharge rates (5.8 C, 3.9 C, and 1.9 C) for similar coolant volume and flow rate. At discharge rates of 5.8 C, a maximum reduction of 30 K and 12 K is obtained with nanofluid compared to air and de-ionized water, respectively, at a lower flow rate. A temperature homogeneity of 5 K is obtained with nanofluid even for a higher discharge rate (5.8 C).

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-02-16
DOI
https://doi.org/10.1016/j.rineng.2025.104377
Citations
8
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
5.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Immersion cooling performance of nanofluid in a cylindrical cell battery pack using two-phase numerical simulations for varying discharge rates: A comparative study

Kottayat Nidhul, Rhik Banerjee
8 citations
Results in Engineering
Advanced Battery Technologies Research
5.46
article

Immersion cooling performance of nanofluid in a cylindrical cell battery pack using two-phase numerical simulations for varying discharge rates: A comparative study

Kottayat Nidhul, Rhik Banerjee
article en
8 citations

Abstract

• Nanofluid with Al2O3 nanoparticles for varying volume fractions (0.1% and 0.4%) using two-phase model. • A maximum reduction of 15 K in the maximum temperature compared to air. • A maximum reduction of 7 K in the maximum temperature compared to de-ionized water. • A temperature homogeneity of 5 K even for a higher discharge rate (5.8 C). Immersion cooling is gaining attention as it does not involve complex flow channels within the battery, making it easier to manufacture a compact battery thermal management system (BTMS) for high-discharge cells that could limit the operation of the battery pack within the optimal temperature range. Initially, forced air cooling performance is studied for various cell arrangements, such as aligned, staggered, and diamond, to arrive at the optimal cylindrical cell battery pack arrangement. The staggered configuration provided the best overall performance with a reduction in maximum temperature and enhancement in Nusselt number of 3.6 and 20 %, respectively, for an increase in pumping power of 25 % at higher discharge rates than aligned. Further, the cooling performance of air is compared to de-ionized water and its nanofluid with Al 2 O 3 nanoparticles for varying volume fractions (0.1% and 0.4%) and discharge rates (5.8 C, 3.9 C, and 1.9 C) for similar coolant volume and flow rate. At discharge rates of 5.8 C, a maximum reduction of 30 K and 12 K is obtained with nanofluid compared to air and de-ionized water, respectively, at a lower flow rate. A temperature homogeneity of 5 K is obtained with nanofluid even for a higher discharge rate (5.8 C).

Results in EngineeringVol. 25
Manipal Academy of Higher Education (IN)
Affordable and clean energy
Openalex Percentile: Top 5%
Advanced Battery Technologies Research
5.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Immersion cooling performance of nanofluid in a cylindrical cell battery pack using two-phase numerical simulations for varying discharge rates: A comparative study — Kottayat Nidhul, Rhik Banerjee · Results in Engineering (2025) | TGRS Research Map | TGRS