Advanced AI-driven techniques for fault and transient analysis in high-voltage power systems

Each substation is critically essential to the overall operation of the electrical power system. Potential dangers include thermal stress, noise, slip, trip, fall hazards, animal waste, and nonionizing radiation. These are the causes of joint failures of cables and overhead lines, failure of one or more phases of circuit breakers, and melting of fuses or conductors in one or more phases. These kinds of failures bring about a decline in the substation's level of dependability. On the consumer side, power cannot be received adequately because there are losses in the transmission line. To accomplish the objective of enhancing the voltage profile, the DG must be optimized. The substation's transient analysis utilizing a variety of factors, a study of faults and transients that occur in the substation and their effects using ETAP, and an optimization of a range of parameters using artificial intelligence techniques are all used for this goal. This paper offers the complete simulation of a 500kv substation. The simulation uses advanced software Electrical Transient Analyzer Program (ETAP) with detailed load flow analysis and short circuit study of the 500 kV substation system using ETAP software. From the ETAP-generated load flow details and the short circuit details, which are studied by varying loads or other parameters, these whole simulations are carried out multiple times using real-time data from the past eighteen months. A simulation data set contains data on both standard and different faulty conditions. In the 1st step, the normal and faulty conditions are classified. In the 2nd step, the reasons for fault occurrence include line-to-line, line-to-ground, and double line-to-ground using the Artificial Intelligence technique. In both steps, Catboost performs well, followed by Support Vector Machine and Logistic Regression. In the first step, Catboost classifies normal and faulty conditions with an accuracy of 98%, SVM is 96%, and Logistic regression is 93%. Again, in the 2nd step to identify different faulty conditions, the accuracies of Catboost SVM and Logistic Regression are 97%, 95%, and 92%, respectively.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-02-15
DOI
https://doi.org/10.1038/s41598-025-90055-7
Citations
20
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
24.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced AI-driven techniques for fault and transient analysis in high-voltage power systems

Muhammad Zain Yousaf, Renhai Feng, Muhammad Abbas, Євген Зайцев et al.
20 citations
Scientific Reports
Power Systems Fault Detection
24.29
article

Advanced AI-driven techniques for fault and transient analysis in high-voltage power systems

Muhammad Zain Yousaf, Renhai Feng, Muhammad Abbas, Євген Зайцев, Wajid Khan, Abdul Aziz, Mohd Redzuan Ahmad, Mohit Bajaj, Umar Siddique
article en
20 citations

Abstract

Each substation is critically essential to the overall operation of the electrical power system. Potential dangers include thermal stress, noise, slip, trip, fall hazards, animal waste, and nonionizing radiation. These are the causes of joint failures of cables and overhead lines, failure of one or more phases of circuit breakers, and melting of fuses or conductors in one or more phases. These kinds of failures bring about a decline in the substation's level of dependability. On the consumer side, power cannot be received adequately because there are losses in the transmission line. To accomplish the objective of enhancing the voltage profile, the DG must be optimized. The substation's transient analysis utilizing a variety of factors, a study of faults and transients that occur in the substation and their effects using ETAP, and an optimization of a range of parameters using artificial intelligence techniques are all used for this goal. This paper offers the complete simulation of a 500kv substation. The simulation uses advanced software Electrical Transient Analyzer Program (ETAP) with detailed load flow analysis and short circuit study of the 500 kV substation system using ETAP software. From the ETAP-generated load flow details and the short circuit details, which are studied by varying loads or other parameters, these whole simulations are carried out multiple times using real-time data from the past eighteen months. A simulation data set contains data on both standard and different faulty conditions. In the 1st step, the normal and faulty conditions are classified. In the 2nd step, the reasons for fault occurrence include line-to-line, line-to-ground, and double line-to-ground using the Artificial Intelligence technique. In both steps, Catboost performs well, followed by Support Vector Machine and Logistic Regression. In the first step, Catboost classifies normal and faulty conditions with an accuracy of 98%, SVM is 96%, and Logistic regression is 93%. Again, in the 2nd step to identify different faulty conditions, the accuracies of Catboost SVM and Logistic Regression are 97%, 95%, and 92%, respectively.

Scientific ReportsVol. 15(1)
Al-Ahliyya Amman University (JO), National Academy of Sciences of Ukraine (UA), Tianjin University (CN), Institute of Electrodynamics (UA), CECOS University (PK), Hubei University of Automotive Technology (CN), University of Business and Technology (SA), Graphic Era University (IN), Zhejiang University (CN), University of Engineering and Technology Peshawar (PK)
Openalex Percentile: Top 0%
Power Systems Fault Detection
24.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines