Heat penetration and thermal response due to firebrand accumulation on the exterior walls of dwellings

This paper presents an extensive experimental investigation campaign concerning the thermal fire reaction of firebrands, as they accumulate on the exterior walls of dwellings, a common occurrence in southern Europe. Three types of wall core layers were studied: bricks, designed according to the Exterior Thermal Insulation Composite Systems (ETICS) methodology, cross-laminated timber (CLT) and normal wood (NW), both utilizing the sandwich methodology. The wall specimens are made of a combination of materials such as three types of mortar (Tria, Sika, and Weber), and various thermal insulation materials, such as agglomerates of composite cork, impermeable membranes, rigid rock wool, fireproof paint, and extruded polystyrene rigid foam (XPS), which are recommended for their good performance against fire and high temperatures. Firebrands are then deposited on the localized surfaces of the wall specimens, and the temperature is recorded in each layer. This study aims to precisely verify the firebrand reaction to fire, including the type of ignition, smoke and droplet production. The insulation capabilities of each insulation and wall system will also be analyzed.

Authors

Institutions

Publication Details

Journal
Journal of Safety Science and Resilience
Published
2025-02-15
DOI
https://doi.org/10.1016/j.jnlssr.2024.12.003
Citations
1
Primary Topic
Fire effects on ecosystems
Type
article
Field-Weighted Citation Impact
1.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat penetration and thermal response due to firebrand accumulation on the exterior walls of dwellings

P. Cantor, Mohamed Zitouni, Fernando A. Branco, M.R.T. Arruda
1 citations
Journal of Safety Science and Resilience
Fire effects on ecosystems
1.11
article

Heat penetration and thermal response due to firebrand accumulation on the exterior walls of dwellings

P. Cantor, Mohamed Zitouni, Fernando A. Branco, M.R.T. Arruda
article en
1 citations

Abstract

This paper presents an extensive experimental investigation campaign concerning the thermal fire reaction of firebrands, as they accumulate on the exterior walls of dwellings, a common occurrence in southern Europe. Three types of wall core layers were studied: bricks, designed according to the Exterior Thermal Insulation Composite Systems (ETICS) methodology, cross-laminated timber (CLT) and normal wood (NW), both utilizing the sandwich methodology. The wall specimens are made of a combination of materials such as three types of mortar (Tria, Sika, and Weber), and various thermal insulation materials, such as agglomerates of composite cork, impermeable membranes, rigid rock wool, fireproof paint, and extruded polystyrene rigid foam (XPS), which are recommended for their good performance against fire and high temperatures. Firebrands are then deposited on the localized surfaces of the wall specimens, and the temperature is recorded in each layer. This study aims to precisely verify the firebrand reaction to fire, including the type of ignition, smoke and droplet production. The insulation capabilities of each insulation and wall system will also be analyzed.

Journal of Safety Science and ResilienceVol. 6(3)
University of Lisbon (PT), National Laboratory for Civil Engineering (PT)
Fundação para a Ciência e a Tecnologia
Sustainable cities and communities
Openalex Percentile: Top 27%
Fire effects on ecosystems
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.