A robust and highly sensitive electrochemical probe for detection of trace levels of NH3/NH4+ in water based on Berthelot's reaction

Traditional spectrochemical methods for quantifying NH 3 /NH 4 + based on the colored oxidation product of Berthelot or Nessler reactions, face challenges due to spectral overlap, auto-self absorbance, background scattering noise and high limits of detection. Thus, the current study introduces a new electrochemical sensing platform utilizing an ex-situ Bi film-plated glassy carbon electrode (BiF/GCE) combined with Berthelot's reaction for detecting trace levels of NH 3 /NH 4 + in water. The primary advantage of Bi as a surface modifier of GCE is its ability to provide a selective and explicit probe for NH 3 /NH 4 + detection at trace levels. This platform employs an ex-situ BiF/GCE, square wave-adsorptive anodic stripping voltammetry (Ads SW-ASV), and the oxidation product of Berthelot's reaction for precise indirect detection of NH 3 /NH 4 + in aqueous solutions at pH 10–11. The probe demonstrated excellent electrochemical performance for NH 3 /NH 4 + detection over a concentration range of 3.2 nM to 20.0 μM, with detection and quantitation limits of 0.95 and 3.2 nM, respectively. It showed good selectivity towards detection of NH 3 /NH 4 + in water with favorable repeatability (RSD = ±3.2 %) and reproducibility (RSD = ±4.1 %). The probe's measurements were validated against standard ion chromatography (IC) and microspectrophotometry methods, demonstrating high reliability for detecting NH 3 /NH 4 + in environmental and Red Sea water samples. This assay is precise and versatile for ammonia detection, enabling measurement of trace levels of N-containing organic compounds in foodstuffs and their degradation products.

Authors

Publication Details

Journal
Sensing and Bio-Sensing Research
Published
2025-02-01
DOI
https://doi.org/10.1016/j.sbsr.2025.100760
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A robust and highly sensitive electrochemical probe for detection of trace levels of NH3/NH4+ in water based on Berthelot's reaction

H. Alwael, Reda Elshafey, Brendan Duffy, M.S. El-Shahawi et al.
1 citations
Sensing and Bio-Sensing Research
Electrochemical sensors and biosensors
0.73
article

A robust and highly sensitive electrochemical probe for detection of trace levels of NH3/NH4+ in water based on Berthelot's reaction

H. Alwael, Reda Elshafey, Brendan Duffy, M.S. El-Shahawi, Abdulrahman S. Alharthi, A. Alsolami, M. Oubah
article en
1 citations

Abstract

Traditional spectrochemical methods for quantifying NH 3 /NH 4 + based on the colored oxidation product of Berthelot or Nessler reactions, face challenges due to spectral overlap, auto-self absorbance, background scattering noise and high limits of detection. Thus, the current study introduces a new electrochemical sensing platform utilizing an ex-situ Bi film-plated glassy carbon electrode (BiF/GCE) combined with Berthelot's reaction for detecting trace levels of NH 3 /NH 4 + in water. The primary advantage of Bi as a surface modifier of GCE is its ability to provide a selective and explicit probe for NH 3 /NH 4 + detection at trace levels. This platform employs an ex-situ BiF/GCE, square wave-adsorptive anodic stripping voltammetry (Ads SW-ASV), and the oxidation product of Berthelot's reaction for precise indirect detection of NH 3 /NH 4 + in aqueous solutions at pH 10–11. The probe demonstrated excellent electrochemical performance for NH 3 /NH 4 + detection over a concentration range of 3.2 nM to 20.0 μM, with detection and quantitation limits of 0.95 and 3.2 nM, respectively. It showed good selectivity towards detection of NH 3 /NH 4 + in water with favorable repeatability (RSD = ±3.2 %) and reproducibility (RSD = ±4.1 %). The probe's measurements were validated against standard ion chromatography (IC) and microspectrophotometry methods, demonstrating high reliability for detecting NH 3 /NH 4 + in environmental and Red Sea water samples. This assay is precise and versatile for ammonia detection, enabling measurement of trace levels of N-containing organic compounds in foodstuffs and their degradation products.

Sensing and Bio-Sensing ResearchVol. 47
Clean water and sanitation
Openalex Percentile: Top 31%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A robust and highly sensitive electrochemical probe for detection of trace levels of NH3/NH4+ in water based on Berthelot's reaction — H. Alwael, Reda Elshafey, et al. · Sensing and Bio-Sensing Research (2025) | TGRS Research Map | TGRS