Microbiological proficiency testing: Establishing a fixed standard deviation for proficiency assessment
The evaluation of use a specific fixed standard deviation for the proficiency assessment (σ pt ) in three Chilean microbiological proficiency testing scheme was discussed in this study. The σ pt proposed in the standards (0.25 and 0.35) was not appropriate for these microbiological schemes. Nevertheless, a better fixed σ pt value was established for that purpose, considering the characteristic of the round in terms of the matrix, included microorganisms (concentration and strain), and target group of participation.
Authors
- Marcos Josué Rupay Vargas
- Sebastián Riquelme
- F Rodriguez
Institutions
- Instituto de Salud Pública de Chile (CL)
Publication Details
- Journal
- Measurement Sensors
- Published
- 2025-02-15
- DOI
- https://doi.org/10.1016/j.measen.2025.101855
- Citations
- 1
- Primary Topic
- Risk and Safety Analysis
- Type
- article
- Field-Weighted Citation Impact
- 1.40