Overcoming analytical limitations with 5-line multi-dynamic Nd isotope measurements by thermal ionisation mass spectrometry

The extinct 146 Sm 142 Nd radio-isotope chronometer is a valuable tool to study the first 500 Myr of Earth's history, although the entire range of variations of the 142 Nd/ 144 Nd ratio in terrestrial materials is on the order of 20 ppm only. The challenge is that measuring small isotope variations needs very high precision measurements (better than 5 ppm), which are difficult to obtain. Here we present high-precision measurements of Nd isotope ratios performed over a period of three years using the latest generation Thermal Ionisation Mass Spectrometer (TIMS) developed by Nu Instruments – Nu TIMS. The Nu TIMS comprises 16 fixed Faraday cups and a zoom optics system that allow 5-line multi-dynamic analyses with the acquisition of three dynamic ratios for all Nd isotopes. This new method, coupled with an enhanced Nd + signal provides precise measurements with internal errors lower than 2 ppm on 142 Nd/ 144 Nd. We assess the performance of the method using multiple measurements of JNdi-1 and AMES Rennes Nd pure standards, together with rock reference materials. For example, typical JNdi-1 measurements performed over a period of 19 months average at 142 Nd/ 144 Nd = 1.1418299 ± 36 (2sd – 3.2 ppm), 143 Nd/ 144 Nd = 0.5121007 ± 10 (2.0 ppm), 145 Nd/ 144 Nd = 0.3484046 ± 6 (1.8 ppm), 148 Nd/ 144 Nd = 0.2415790 ± 10 (4.1 ppm) and 150 Nd/ 144 Nd = 0.2364481 ± 27 (11.3 ppm). With such precision and accuracy, subtle variations of 142 Nd/ 144 Nd ratios, as low as 3 ppm, can now be detected in natural samples. Minute differences in 145 Nd/ 144 Nd, 148 Nd/ 144 Nd and 150 Nd/ 144 Nd ratios can now also be detected in natural samples, allowing better identification of nucleosynthetic anomalies in extra-terrestrial samples. For terrestrial samples, it allows detection of traces of samarium, and of nuclear field shift effect due to analytical issues. In particular, we demonstrate that some Sm is present in the JNdi-1 standard and affects both its 148 Nd/ 144 Nd and 150 Nd/ 144 Nd ratios, making a systematic interference correction necessary. By detecting the existence of nuclear field shift effect on Nd isotopes, we can now prevent mis-interpretations of 142 Nd/ 144 Nd deviations that could be wrongly attributed to radiogenic signatures acquired during the Hadean. • 5-line multi-dynamic acquisition method for all Nd isotopes using a Nu TIMS. • Improved reproducibility for all Nd isotope ratios. • Analytical bias such as NFS effect and isobaric interferences are better detectable.

Authors

Institutions

Publication Details

Journal
Chemical Geology
Published
2025-02-15
DOI
https://doi.org/10.1016/j.chemgeo.2025.122686
Citations
1
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Overcoming analytical limitations with 5-line multi-dynamic Nd isotope measurements by thermal ionisation mass spectrometry

Daniel K. Roberts, Edward Inglis, Tu-Han Luu, Claudine Israel et al.
1 citations
Chemical Geology
Nuclear Physics and Applications
1.88
article

Overcoming analytical limitations with 5-line multi-dynamic Nd isotope measurements by thermal ionisation mass spectrometry

Daniel K. Roberts, Edward Inglis, Tu-Han Luu, Claudine Israel, Catherine Chauvel
article en
1 citations

Abstract

The extinct 146 Sm 142 Nd radio-isotope chronometer is a valuable tool to study the first 500 Myr of Earth's history, although the entire range of variations of the 142 Nd/ 144 Nd ratio in terrestrial materials is on the order of 20 ppm only. The challenge is that measuring small isotope variations needs very high precision measurements (better than 5 ppm), which are difficult to obtain. Here we present high-precision measurements of Nd isotope ratios performed over a period of three years using the latest generation Thermal Ionisation Mass Spectrometer (TIMS) developed by Nu Instruments – Nu TIMS. The Nu TIMS comprises 16 fixed Faraday cups and a zoom optics system that allow 5-line multi-dynamic analyses with the acquisition of three dynamic ratios for all Nd isotopes. This new method, coupled with an enhanced Nd + signal provides precise measurements with internal errors lower than 2 ppm on 142 Nd/ 144 Nd. We assess the performance of the method using multiple measurements of JNdi-1 and AMES Rennes Nd pure standards, together with rock reference materials. For example, typical JNdi-1 measurements performed over a period of 19 months average at 142 Nd/ 144 Nd = 1.1418299 ± 36 (2sd – 3.2 ppm), 143 Nd/ 144 Nd = 0.5121007 ± 10 (2.0 ppm), 145 Nd/ 144 Nd = 0.3484046 ± 6 (1.8 ppm), 148 Nd/ 144 Nd = 0.2415790 ± 10 (4.1 ppm) and 150 Nd/ 144 Nd = 0.2364481 ± 27 (11.3 ppm). With such precision and accuracy, subtle variations of 142 Nd/ 144 Nd ratios, as low as 3 ppm, can now be detected in natural samples. Minute differences in 145 Nd/ 144 Nd, 148 Nd/ 144 Nd and 150 Nd/ 144 Nd ratios can now also be detected in natural samples, allowing better identification of nucleosynthetic anomalies in extra-terrestrial samples. For terrestrial samples, it allows detection of traces of samarium, and of nuclear field shift effect due to analytical issues. In particular, we demonstrate that some Sm is present in the JNdi-1 standard and affects both its 148 Nd/ 144 Nd and 150 Nd/ 144 Nd ratios, making a systematic interference correction necessary. By detecting the existence of nuclear field shift effect on Nd isotopes, we can now prevent mis-interpretations of 142 Nd/ 144 Nd deviations that could be wrongly attributed to radiogenic signatures acquired during the Hadean. • 5-line multi-dynamic acquisition method for all Nd isotopes using a Nu TIMS. • Improved reproducibility for all Nd isotope ratios. • Analytical bias such as NFS effect and isobaric interferences are better detectable.

Chemical GeologyVol. 680
Centre National de la Recherche Scientifique (FR), Institut de physique du globe de Paris (FR), Université Paris Cité (FR)
Agence Nationale de la Recherche, Institut de Physique du Globe de Paris, Université de Paris
Affordable and clean energy
Openalex Percentile: Top 21%
Nuclear Physics and Applications
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.