A numerical study on the penetrability and directivity of the difference-frequency component beam in bubbly liquids obtained via parametric acoustic array

The penetrability and directivity of ultrasound in different media is of interest in engineering and medical applications (imaging, nondestructive testing, sonochemistry, among others). The nonlinearity of a liquid can be used in the parametric antenna framework to generate low-frequency components with particular features from several ultrasonic signals at the source. Bubbly liquids are dispersive liquids in which a small amount of tiny gas bubbles leads to the increase of the nonlinear parameter of the media over certain frequency ranges. Parametric antenna applied to these huge nonlinear media give rise to low-frequency components with relatively small intensity at the source. The evolution of a low-frequency component (difference-frequency component obtained from two primary signals) during its propagation in a bubbly liquid is somehow unknown. It is thus interesting to analyze its characteristics to establish whether this component can benefit from the quality of its own frequency and from the primary frequencies, in terms of directivity and penetrability into the medium. It must be noted that no such study in bubbly liquids exists in the literature, but only for homogeneous media. The aim of this work is to fill this gap. To this end, several numerical models developed previously are used here to analyze the difference-frequency component obtained from a parametric antenna emitting from two ultrasonic signals at the source in one and two-dimensional domains. These models allow us to observe the behavior of this frequency component. An angle that measures the directivity of a beam is also defined. Our results show a point hardly found in the literature: the high directivity and the huge penetrability of the secondary beam associated to the difference-frequency component into the bubbly liquid, compared to the same frequency signal excited directly from the source in the bubbly liquid and to the parametric acoustic array in homogeneous fluids. • We present a numerical study on the parametric acoustic array in bubbly liquids. • The penetrability and directivity of the secondary ultrasonic beam are studied. • We show that both are very high compared to direct signals and homogeneous fluids. • An angle that measures the directivity of the beam is defined.

Authors

Institutions

Publication Details

Journal
Wave Motion
Published
2025-02-15
DOI
https://doi.org/10.1016/j.wavemoti.2025.103513
Primary Topic
Ultrasound and Cavitation Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A numerical study on the penetrability and directivity of the difference-frequency component beam in bubbly liquids obtained via parametric acoustic array

Christian Vanhille, María Teresa Tejedor Sastre
2 links
Wave Motion
Ultrasound and Cavitation Phenomena
article

A numerical study on the penetrability and directivity of the difference-frequency component beam in bubbly liquids obtained via parametric acoustic array

Christian Vanhille, María Teresa Tejedor Sastre
article en

Abstract

The penetrability and directivity of ultrasound in different media is of interest in engineering and medical applications (imaging, nondestructive testing, sonochemistry, among others). The nonlinearity of a liquid can be used in the parametric antenna framework to generate low-frequency components with particular features from several ultrasonic signals at the source. Bubbly liquids are dispersive liquids in which a small amount of tiny gas bubbles leads to the increase of the nonlinear parameter of the media over certain frequency ranges. Parametric antenna applied to these huge nonlinear media give rise to low-frequency components with relatively small intensity at the source. The evolution of a low-frequency component (difference-frequency component obtained from two primary signals) during its propagation in a bubbly liquid is somehow unknown. It is thus interesting to analyze its characteristics to establish whether this component can benefit from the quality of its own frequency and from the primary frequencies, in terms of directivity and penetrability into the medium. It must be noted that no such study in bubbly liquids exists in the literature, but only for homogeneous media. The aim of this work is to fill this gap. To this end, several numerical models developed previously are used here to analyze the difference-frequency component obtained from a parametric antenna emitting from two ultrasonic signals at the source in one and two-dimensional domains. These models allow us to observe the behavior of this frequency component. An angle that measures the directivity of a beam is also defined. Our results show a point hardly found in the literature: the high directivity and the huge penetrability of the secondary beam associated to the difference-frequency component into the bubbly liquid, compared to the same frequency signal excited directly from the source in the bubbly liquid and to the parametric acoustic array in homogeneous fluids. • We present a numerical study on the parametric acoustic array in bubbly liquids. • The penetrability and directivity of the secondary ultrasonic beam are studied. • We show that both are very high compared to direct signals and homogeneous fluids. • An angle that measures the directivity of the beam is defined.

Wave MotionVol. 135
Universidad Rey Juan Carlos (ES)
Agencia Estatal de Investigación
Openalex Percentile: Top 98%
Ultrasound and Cavitation Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.