Combined X-ray microdiffraction and micromechanical testing for direct measurement of thin film elastic constants

Direct measurement of elastic constants for thin films is still far from routine and poses significant technical and analytical challenges compared to bulk materials. Ab initio Density Functional Theory calculations offer theoretical input, however, discrepancies between model systems and real-world properties persist, primarily due to a lack of available experimental data for newly emerging material systems. Moreover, computationally affordable models are typically limited to defect-free single crystals, omitting microstructural effects that strongly influence the material's behavior. This study addresses this gap by proposing a novel experimental approach to measure direction-dependent elastic constants, combining synchrotron microdiffraction and micropillar compression, testing a polycrystalline face-centered cubic TiN0.8B0.2 thin film, where linear elastic failure prevails. We have established an advanced in-situ testing environment to continuously record the load-displacement of the indenter while simultaneously collecting the material's deformation response to uniform uniaxial compression. This dynamic approach allows the evaluation of the orientation-dependent elastic strain components and the macroscopic uniaxial compressive stresses, each over time, enabling a differential analysis to assess the elastic and X-ray elastic constants. The excellent agreement between experimental and ab initio data solidifies the hereproposed robust method for direct elastic constant measurements, which is crucial for advancements in thin film material testing.

Authors

Publication Details

Journal
Materials & Design
Published
2025-02-15
DOI
https://doi.org/10.1016/j.matdes.2025.113720
Citations
1
Primary Topic
Metal and Thin Film Mechanics
Type
article
Field-Weighted Citation Impact
0.86

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combined X-ray microdiffraction and micromechanical testing for direct measurement of thin film elastic constants

Juraj Todt, Nikola Koutná, H. Riedl, P.H. Mayrhofer et al.
1 citations
Materials & Design
Metal and Thin Film Mechanics
0.86
article

Combined X-ray microdiffraction and micromechanical testing for direct measurement of thin film elastic constants

Juraj Todt, Nikola Koutná, H. Riedl, P.H. Mayrhofer, Michael Meindlhumer, Anton Davydok, Rainer Hahn, Jozef Kečkéš, Rebecca Janknecht
article en
1 citations

Abstract

Direct measurement of elastic constants for thin films is still far from routine and poses significant technical and analytical challenges compared to bulk materials. Ab initio Density Functional Theory calculations offer theoretical input, however, discrepancies between model systems and real-world properties persist, primarily due to a lack of available experimental data for newly emerging material systems. Moreover, computationally affordable models are typically limited to defect-free single crystals, omitting microstructural effects that strongly influence the material's behavior. This study addresses this gap by proposing a novel experimental approach to measure direction-dependent elastic constants, combining synchrotron microdiffraction and micropillar compression, testing a polycrystalline face-centered cubic TiN0.8B0.2 thin film, where linear elastic failure prevails. We have established an advanced in-situ testing environment to continuously record the load-displacement of the indenter while simultaneously collecting the material's deformation response to uniform uniaxial compression. This dynamic approach allows the evaluation of the orientation-dependent elastic strain components and the macroscopic uniaxial compressive stresses, each over time, enabling a differential analysis to assess the elastic and X-ray elastic constants. The excellent agreement between experimental and ab initio data solidifies the hereproposed robust method for direct elastic constant measurements, which is crucial for advancements in thin film material testing.

Materials & DesignVol. 252
Österreichische Nationalstiftung für Forschung, Technologie und Entwicklung, Linköpings Universitet, Vetenskapsrådet, Technische Universität Wien, Christian Doppler Forschungsgesellschaft, International Union for Vacuum Science, Technique, and Applications, Bundesministerium für Digitalisierung und Wirtschaftsstandort, Deutsches Elektronen-Synchrotron, Technische Universität Wien Bibliothek
Openalex Percentile: Top 34%
Metal and Thin Film Mechanics
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.