Experimental validation of absolute full energy peak efficiency and energy resolution of NaI(Tl), CsI(Tl), BGO, YAP(Ce) and CeBr3 scintillation detectors modeled with Monte Carlo codes

Gamma ray spectroscopy has been used extensively for advanced studies in nuclear medicine, industry, and scientific research. Progress in modern high speed computers has allowed the development of sophisticated Monte Carlo simulation codes which can accurately model the time and energy response of gamma spectroscopy detectors and estimate performance parameters. The purpose of this work is to study results from simulation of scintillation detectors for gamma spectroscopy applications. Simulations were performed for three state-of-the-art Monte Carlo transport programs, OpenMC, Geant4 and MCNPX. For each, a model accurately approximating the geometry, dimensions and materials corresponding to the scintillators in real gamma spectroscopy experiments was created. Simulations were run for five different types of inorganic scintillation detectors – NaI(Tl), CsI(Tl), BGO, YAP(Ce) and CeBr 3 - for a wide range of incident gamma ray energies from 32 keV to 1408 keV. The gamma rays chosen correspond to well-known energies from commonly available radionuclide calibration sources, namely 241 Am, 22 Na, 133 Ba, 152 Eu, 137 Cs and 60 Co. Common detector performance parameters were extracted for each simulation program, including absolute full energy peak efficiency and energy resolution. Estimates from simulations of the latter two parameters were compared to experimental data for several gamma sources under the same or very similar conditions, including varying source-to-detector distance to validate the simulation models and the performance of the different simulation codes. • Experimental and Monte Carlo simulated energy spectrum of γ-rays with NaI(Tl), CsI(Tl), BGO, YAP(Ce) and CeBr 3 detectors. • Absolute efficiency and energy resolution of NaI(Tl), CsI(Tl), BGO, YAP(Ce) and CeBr 3 scintillation detectors. • Comparison of experimental detector efficiencies with those from three of the most popular Monte Carlo programs. • Comparison of experimental detector energy resolutions with those from one of the Monte Carlo programs.

Authors

Publication Details

Journal
Radiation Physics and Chemistry
Published
2025-02-15
DOI
https://doi.org/10.1016/j.radphyschem.2025.112603
Citations
3
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
5.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental validation of absolute full energy peak efficiency and energy resolution of NaI(Tl), CsI(Tl), BGO, YAP(Ce) and CeBr3 scintillation detectors modeled with Monte Carlo codes

M. Bellioua, Mohamed Drissi El-Bouzaidi, John E. McFee, El Houssaine Ouacha et al.
3 citations
Radiation Physics and Chemistry
Radiation Detection and Scintillator Technologies
5.65
article

Experimental validation of absolute full energy peak efficiency and energy resolution of NaI(Tl), CsI(Tl), BGO, YAP(Ce) and CeBr3 scintillation detectors modeled with Monte Carlo codes

M. Bellioua, Mohamed Drissi El-Bouzaidi, John E. McFee, El Houssaine Ouacha, Jamal El Qars, Issam Mouhti, M’hand Assakrar
article en
3 citations

Abstract

Gamma ray spectroscopy has been used extensively for advanced studies in nuclear medicine, industry, and scientific research. Progress in modern high speed computers has allowed the development of sophisticated Monte Carlo simulation codes which can accurately model the time and energy response of gamma spectroscopy detectors and estimate performance parameters. The purpose of this work is to study results from simulation of scintillation detectors for gamma spectroscopy applications. Simulations were performed for three state-of-the-art Monte Carlo transport programs, OpenMC, Geant4 and MCNPX. For each, a model accurately approximating the geometry, dimensions and materials corresponding to the scintillators in real gamma spectroscopy experiments was created. Simulations were run for five different types of inorganic scintillation detectors – NaI(Tl), CsI(Tl), BGO, YAP(Ce) and CeBr 3 - for a wide range of incident gamma ray energies from 32 keV to 1408 keV. The gamma rays chosen correspond to well-known energies from commonly available radionuclide calibration sources, namely 241 Am, 22 Na, 133 Ba, 152 Eu, 137 Cs and 60 Co. Common detector performance parameters were extracted for each simulation program, including absolute full energy peak efficiency and energy resolution. Estimates from simulations of the latter two parameters were compared to experimental data for several gamma sources under the same or very similar conditions, including varying source-to-detector distance to validate the simulation models and the performance of the different simulation codes. • Experimental and Monte Carlo simulated energy spectrum of γ-rays with NaI(Tl), CsI(Tl), BGO, YAP(Ce) and CeBr 3 detectors. • Absolute efficiency and energy resolution of NaI(Tl), CsI(Tl), BGO, YAP(Ce) and CeBr 3 scintillation detectors. • Comparison of experimental detector efficiencies with those from three of the most popular Monte Carlo programs. • Comparison of experimental detector energy resolutions with those from one of the Monte Carlo programs.

Radiation Physics and ChemistryVol. 231
Affordable and clean energy
Openalex Percentile: Top 5%
Radiation Detection and Scintillator Technologies
5.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.