Modeling and Performance Assessment of AN SGT5- 2000E Gas Turbine in AZURA Power Plant

This study evaluates the performance of the SGT5- 2000E gas turbine at the Azura Power Plant, Benin City, Nigeria, under a simple cycle configuration using GasTurb 14 software. Simulations were conducted to examine the effects of varying ambient temperature, relative humidity, and turbine inlet temperature (TIT) on key performance parameters. The results revealed that increased TIT significantly improved both power output and thermal efficiency. For instance, a TIT of 1109.7 °C resulted in a power output of 159.5 MW, a thermal efficiency of 35.14%, and a heat rate of 10,228 kJ/kWh. Ambient temperature variations demonstrated an inverse relationship with power output and thermal efficiency, with lower temperatures yielding higher performance. Similarly, increased relative humidity positively influenced power output and reduced specific fuel consumption. These findings highlight the critical influence of environmental conditions and TIT optimization on the operational efficiency of gas turbines in simple cycle mode, providing valuable insights for enhancing performance in similar energy setups.

Authors

Publication Details

Journal
International Journal of Advances in Engineering and Management
Published
2025-02-01
DOI
https://doi.org/10.35629/5252-07026171
Primary Topic
Advanced Power Generation Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling and Performance Assessment of AN SGT5- 2000E Gas Turbine in AZURA Power Plant

Aisha Sa’ad, Wunuken Carlos Solomon, Esene John Omokiere
International Journal of Advances in Engineering and Management
Advanced Power Generation Technologies
article

Modeling and Performance Assessment of AN SGT5- 2000E Gas Turbine in AZURA Power Plant

Aisha Sa’ad, Wunuken Carlos Solomon, Esene John Omokiere
article en

Abstract

This study evaluates the performance of the SGT5- 2000E gas turbine at the Azura Power Plant, Benin City, Nigeria, under a simple cycle configuration using GasTurb 14 software. Simulations were conducted to examine the effects of varying ambient temperature, relative humidity, and turbine inlet temperature (TIT) on key performance parameters. The results revealed that increased TIT significantly improved both power output and thermal efficiency. For instance, a TIT of 1109.7 °C resulted in a power output of 159.5 MW, a thermal efficiency of 35.14%, and a heat rate of 10,228 kJ/kWh. Ambient temperature variations demonstrated an inverse relationship with power output and thermal efficiency, with lower temperatures yielding higher performance. Similarly, increased relative humidity positively influenced power output and reduced specific fuel consumption. These findings highlight the critical influence of environmental conditions and TIT optimization on the operational efficiency of gas turbines in simple cycle mode, providing valuable insights for enhancing performance in similar energy setups.

International Journal of Advances in Engineering and ManagementVol. 7(2)
Openalex Percentile: Top 98%
Advanced Power Generation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modeling and Performance Assessment of AN SGT5- 2000E Gas Turbine in AZURA Power Plant — Aisha Sa’ad, Wunuken Carlos Solomon, et al. · International Journal of Advances in Engineering and Management (2025) | TGRS Research Map | TGRS