Speech Detection via Respiratory Inductance Plethysmography, Thoracic Impedance, Accelerometers, and Gyroscopes: A Machine Learning‐Informed Comparative Study

Speech production interferes with the measurement of changes in cardiac vagal activity during acute stress by attenuating the expected drop in heart rate variability. Speech also induces cardiac sympathetic changes similar to those induced by psychological stress. In the laboratory, confounding of physiological stress reactivity by speech may be controlled experimentally. In ambulatory assessments, however, detection of speech episodes would be necessary to separate the physiological effects of psychosocial stress from those of speech. Using machine learning (https://osf.io/bk9nf), we trained and tested speech classification models on data from 56 participants (ages 18-39) under controlled laboratory conditions. They were equipped with privacy-secure wearables measuring thoracoabdominal respiratory inductance plethysmography (RIP from a single and a dual-band set-up), thoracic impedance pneumography, and an upper sternum positioned unit with triaxial accelerometers and gyroscopes. Following an 80/20 train-test split, nested cross-validations were run with the machine learning algorithms XGBoost, gradient boosting, random forest, and logistic regression on the training set to get generalized performance estimates. Speech classification by the best model per method was then validated in the test set. Speech versus no-speech classification performance (AUC) for both nested cross-validation and test set predictions was excellent for thorax-abdomen RIP (nested cross-validation: 96.6%, test set prediction: 98.5%), thorax-only RIP (97.5%, 99.1%), impedance (97.0%, 97.8%), and accelerometry (99.3%, 99.6%). The sternal accelerometer method outperformed others. These open-access models leveraging biosignals have the potential to also work in daily life settings. This could enhance the trustworthiness of ambulatory psychophysiology, by enabling detection of speech and controlling for its confounding effects on physiology.

Authors

Institutions

Publication Details

Journal
Psychophysiology
Published
2025-02-01
DOI
https://doi.org/10.1111/psyp.70021
Citations
3
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Speech Detection via Respiratory Inductance Plethysmography, Thoracic Impedance, Accelerometers, and Gyroscopes: A Machine Learning‐Informed Comparative Study

Martin Gevonden, Eco J. C. de Geus, Melisa Saygin, Myrte Schoenmakers
3 citations
Psychophysiology
Non-Invasive Vital Sign Monitoring
2.02
article

Speech Detection via Respiratory Inductance Plethysmography, Thoracic Impedance, Accelerometers, and Gyroscopes: A Machine Learning‐Informed Comparative Study

Martin Gevonden, Eco J. C. de Geus, Melisa Saygin, Myrte Schoenmakers
article en
3 citations

Abstract

Speech production interferes with the measurement of changes in cardiac vagal activity during acute stress by attenuating the expected drop in heart rate variability. Speech also induces cardiac sympathetic changes similar to those induced by psychological stress. In the laboratory, confounding of physiological stress reactivity by speech may be controlled experimentally. In ambulatory assessments, however, detection of speech episodes would be necessary to separate the physiological effects of psychosocial stress from those of speech. Using machine learning (https://osf.io/bk9nf), we trained and tested speech classification models on data from 56 participants (ages 18-39) under controlled laboratory conditions. They were equipped with privacy-secure wearables measuring thoracoabdominal respiratory inductance plethysmography (RIP from a single and a dual-band set-up), thoracic impedance pneumography, and an upper sternum positioned unit with triaxial accelerometers and gyroscopes. Following an 80/20 train-test split, nested cross-validations were run with the machine learning algorithms XGBoost, gradient boosting, random forest, and logistic regression on the training set to get generalized performance estimates. Speech classification by the best model per method was then validated in the test set. Speech versus no-speech classification performance (AUC) for both nested cross-validation and test set predictions was excellent for thorax-abdomen RIP (nested cross-validation: 96.6%, test set prediction: 98.5%), thorax-only RIP (97.5%, 99.1%), impedance (97.0%, 97.8%), and accelerometry (99.3%, 99.6%). The sternal accelerometer method outperformed others. These open-access models leveraging biosignals have the potential to also work in daily life settings. This could enhance the trustworthiness of ambulatory psychophysiology, by enabling detection of speech and controlling for its confounding effects on physiology.

PsychophysiologyVol. 62(2)
Amsterdam University Medical Centers (NL), Vrije Universiteit Amsterdam (NL)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Peace, Justice and strong institutions
Openalex Percentile: Top 16%
Non-Invasive Vital Sign Monitoring
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.