Buck Converter Scheme with High Transient Response

This paper proposed the buck converter with a high transient response. This control scheme is derived from the current mode control (CMC) architecture to further improve its transient performance. The advantages of the converter are as follows: (a) Superior transient response. The recovery time for step-up/step-down is within 1.6[Formula: see text] [Formula: see text]s. (b) The structure of the scheme is simple and easy to implement. (c) For an input voltage of 3.0–3.6[Formula: see text]V and output voltage of 1.0–2.5[Formula: see text]V, the converter maintains a constant switching frequency. This feature solves the EMI issue in applications. (d) Although the proposed scheme is derived from the CMC architecture, it does not require a current sensor. The control topology, analysis, operation principle and circuit realization of the converter are presented in this paper. In the future, the proposed circuits can be fabricated by UMC 0.18[Formula: see text] [Formula: see text]m 1P6M CMOS processes.

Authors

Institutions

Publication Details

Journal
Journal of Circuits Systems and Computers
Published
2025-02-15
DOI
https://doi.org/10.1142/s0218126625502251
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Buck Converter Scheme with High Transient Response

Jia-Ruei Cho, Hsin-Liang Chen, Hsiao-Hsing Chou, Jun-You Lin
Journal of Circuits Systems and Computers
Advanced DC-DC Converters
article

Buck Converter Scheme with High Transient Response

Jia-Ruei Cho, Hsin-Liang Chen, Hsiao-Hsing Chou, Jun-You Lin
article en

Abstract

This paper proposed the buck converter with a high transient response. This control scheme is derived from the current mode control (CMC) architecture to further improve its transient performance. The advantages of the converter are as follows: (a) Superior transient response. The recovery time for step-up/step-down is within 1.6[Formula: see text] [Formula: see text]s. (b) The structure of the scheme is simple and easy to implement. (c) For an input voltage of 3.0–3.6[Formula: see text]V and output voltage of 1.0–2.5[Formula: see text]V, the converter maintains a constant switching frequency. This feature solves the EMI issue in applications. (d) Although the proposed scheme is derived from the CMC architecture, it does not require a current sensor. The control topology, analysis, operation principle and circuit realization of the converter are presented in this paper. In the future, the proposed circuits can be fabricated by UMC 0.18[Formula: see text] [Formula: see text]m 1P6M CMOS processes.

Journal of Circuits Systems and ComputersVol. 34(10)
Tamkang University (TW), National Taichung University of Science and Technology (TW)
Openalex Percentile: Top 98%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.