Temperature dependence compensation of X-ray spectrometry with MiniPIX Timepix3 SiC detector

Abstract Timepix3 is a hybrid pixel radiation detector, from the CERN-designed Timepix family, which contains 65.536 pixels. The detectors based on Timepix3 read-out chips have started to be used in a wide range of applications, such as medicine, particle physics, neutron detection and space applications. For applications in harsh environments such as space, particle therapy and nuclear power engineering, silicon carbide (SiC) stands as suitable semiconductor sensor thanks to its chemical stability, wide temperature operation range and enhanced radiation hardness. Newly developed MiniPIX Timepix3 SiC cameras are undergoing physical and operating tests for various applications. Since their main applications are in harsh environments where they are exposed to a wide range of temperatures, it is important to examine and describe the behaviour of these detectors under the influence of different temperatures. Consequently, it is necessary to compensate these temperature effects. Thus, this study investigates the temperature dependence of the spectral (deposited energy) response of the Timepix3 detectors equipped with a 4H-SiC sensor over a temperature range of 10 ∘ C to 60 ∘ C, with a per-pixel energy calibration performed at 20 ∘ C. The detector was exposed to fluorescence X-rays with energies between 8 keV and 58 keV and between 31 keV and 40 keV from the radioactive sources 133 Ba and 152 Eu, respectively. It was found that with increasing temperature there is a shift of the energy spectra to lower values, which increases with increasing incident energy. A compensation method is proposed to correct for the distortion in the measured energy range.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-02-01
DOI
https://doi.org/10.1088/1748-0221/20/02/c02033
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature dependence compensation of X-ray spectrometry with MiniPIX Timepix3 SiC detector

Bohumír Zaťko, Carlos Granja, D. Hladik, Nikola Kurucová
Journal of Instrumentation
Particle Detector Development and Performance
article

Temperature dependence compensation of X-ray spectrometry with MiniPIX Timepix3 SiC detector

Bohumír Zaťko, Carlos Granja, D. Hladik, Nikola Kurucová
article en

Abstract

Abstract Timepix3 is a hybrid pixel radiation detector, from the CERN-designed Timepix family, which contains 65.536 pixels. The detectors based on Timepix3 read-out chips have started to be used in a wide range of applications, such as medicine, particle physics, neutron detection and space applications. For applications in harsh environments such as space, particle therapy and nuclear power engineering, silicon carbide (SiC) stands as suitable semiconductor sensor thanks to its chemical stability, wide temperature operation range and enhanced radiation hardness. Newly developed MiniPIX Timepix3 SiC cameras are undergoing physical and operating tests for various applications. Since their main applications are in harsh environments where they are exposed to a wide range of temperatures, it is important to examine and describe the behaviour of these detectors under the influence of different temperatures. Consequently, it is necessary to compensate these temperature effects. Thus, this study investigates the temperature dependence of the spectral (deposited energy) response of the Timepix3 detectors equipped with a 4H-SiC sensor over a temperature range of 10 ∘ C to 60 ∘ C, with a per-pixel energy calibration performed at 20 ∘ C. The detector was exposed to fluorescence X-rays with energies between 8 keV and 58 keV and between 31 keV and 40 keV from the radioactive sources 133 Ba and 152 Eu, respectively. It was found that with increasing temperature there is a shift of the energy spectra to lower values, which increases with increasing incident energy. A compensation method is proposed to correct for the distortion in the measured energy range.

Journal of InstrumentationVol. 20(02)
Slovak University of Technology in Bratislava (SK), Institute of Chemistry of the Slovak Academy of Sciences (SK), Slovak Academy of Sciences (SK), Institute of Electrical Engineering of the Slovak Academy of Sciences (SK), Advacam (Czechia) (CZ)
Openalex Percentile: Top 98%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.