Deep-learning-based automatic patient motion correction for 18F-flurpiridaz PET-MPI

Accurate quantification of myocardial blood flow (MBF) and flow reserve (MFR) myocardial perfusion imaging (MPI) is critically dependent on effective inter-frame motion correction (MC) in the dynamic stress and rest scans. Manual frameby- frame correction is both time-consuming and prone to significant interobserver variability. <strong>Methods</strong>: We propose a deep learning (DL) framework for MC of <sup>18</sup>F-flurpiridaz PET-MPI using 3D Resnet based architecture with added positional embeddings. Positional embedding gives the network context regarding the frame number, adding temporal dimension to the network. We trained the model on 116 stress and rest studies from the Phase III Flurpiridaz trial (NCT01347710). All patient scans were dynamic, and each frame was treated as an independent training and test data point. Manual MC was performed by two experienced operators with clinical software and their corrections served as ground truth data for training the network. The output of the model was the predicted translation vector (t<sub>x</sub>, t<sub>y</sub>, t<sub>z</sub>) to correct for motion. The model's performance was assessed through inference on a separate unseen test dataset comprising 117 patient scans. <strong>Results</strong>: DL MC takes 1-2 seconds for inference per scan which is significantly faster than manual MC which takes about 10 minutes per scan with 26 frames with comparable results. The root mean square error between the predicted and targets of the test set was 1.2mm, 1.04mm and 2.28mm in x, y and z directions respectively. <strong>Conclusion</strong>: DL model trained on user MC vectors provides faster method for automatic inter-frame MC for dynamic PET-MPI <sup>18</sup>F-flurpiridaz and may automate and objectify the analysis of the myocardial blood flow.

Authors

Institutions

Publication Details

Published
2025-02-15
DOI
https://doi.org/10.1117/12.3047482
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep-learning-based automatic patient motion correction for 18F-flurpiridaz PET-MPI

Aditya Killekar, Paul Kavanagh, Mark A. Lemley, Piotr J. Slomka et al.
Medical Imaging Techniques and Applications
article

Deep-learning-based automatic patient motion correction for 18F-flurpiridaz PET-MPI

Aditya Killekar, Paul Kavanagh, Mark A. Lemley, Piotr J. Slomka, Meghana Urs, Chih-Chun Wei, Valerie Builoff
article en

Abstract

Accurate quantification of myocardial blood flow (MBF) and flow reserve (MFR) myocardial perfusion imaging (MPI) is critically dependent on effective inter-frame motion correction (MC) in the dynamic stress and rest scans. Manual frameby- frame correction is both time-consuming and prone to significant interobserver variability. <strong>Methods</strong>: We propose a deep learning (DL) framework for MC of <sup>18</sup>F-flurpiridaz PET-MPI using 3D Resnet based architecture with added positional embeddings. Positional embedding gives the network context regarding the frame number, adding temporal dimension to the network. We trained the model on 116 stress and rest studies from the Phase III Flurpiridaz trial (NCT01347710). All patient scans were dynamic, and each frame was treated as an independent training and test data point. Manual MC was performed by two experienced operators with clinical software and their corrections served as ground truth data for training the network. The output of the model was the predicted translation vector (t<sub>x</sub>, t<sub>y</sub>, t<sub>z</sub>) to correct for motion. The model's performance was assessed through inference on a separate unseen test dataset comprising 117 patient scans. <strong>Results</strong>: DL MC takes 1-2 seconds for inference per scan which is significantly faster than manual MC which takes about 10 minutes per scan with 26 frames with comparable results. The root mean square error between the predicted and targets of the test set was 1.2mm, 1.04mm and 2.28mm in x, y and z directions respectively. <strong>Conclusion</strong>: DL model trained on user MC vectors provides faster method for automatic inter-frame MC for dynamic PET-MPI <sup>18</sup>F-flurpiridaz and may automate and objectify the analysis of the myocardial blood flow.

Cedars-Sinai Medical Center (US)
Openalex Percentile: Top 96%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Deep-learning-based automatic patient motion correction for 18F-flurpiridaz PET-MPI — Aditya Killekar, Paul Kavanagh, et al. · (2025) | TGRS Research Map | TGRS