Comparison of coefficient of performance (COP) values in training kits for air conditioning systems in cars with condensation using air and water

This research aims to compare the coefficient of performance (COP) of the air conditioning system in a car training kit that uses two different types of condensation, namely using air and water. The research was carried out by implementing these two condensation methods in a car AC system in a training kit designed to simulate real conditions. The data collection method involves measuring the energy consumption and cooling efficiency of both systems. Testing is carried out in various environmental conditions which include variations in temperature, humidity, and other operational conditions that can affect the performance of each system. The research results show a comparison of COP between air conditioning systems that use air and water condensation. The findings show that systems using air condensation have a lower COP, namely 2.24, compared to systems using water condensation with a value of 2.53 in a certain range of conditions. The efficiency of both systems is also influenced by certain environmental factors, but the efficiency value for condensation with air remains lower with a value of 56.92, while with water condensation with a value of 65.10, this gives an indication that condensation using water is better in the air conditioning system in cars. The conclusion of this research is that both condensation methods have their respective advantages and disadvantages in terms of efficiency and performance.

Authors

Institutions

Publication Details

Journal
BIS Energy and Engineering
Published
2024-11-10
DOI
https://doi.org/10.31603/biseeng.10
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of coefficient of performance (COP) values in training kits for air conditioning systems in cars with condensation using air and water

Nuraini Lusi, Marcella Milana, M. Yasep Setiawan, Nuzul Hidayat et al.
1 citations
BIS Energy and Engineering
Refrigeration and Air Conditioning Technologies
0.21
article

Comparison of coefficient of performance (COP) values in training kits for air conditioning systems in cars with condensation using air and water

Nuraini Lusi, Marcella Milana, M. Yasep Setiawan, Nuzul Hidayat, Wawan Aries Widodo, Juli Sardi, A Ikhlas
article en
1 citations

Abstract

This research aims to compare the coefficient of performance (COP) of the air conditioning system in a car training kit that uses two different types of condensation, namely using air and water. The research was carried out by implementing these two condensation methods in a car AC system in a training kit designed to simulate real conditions. The data collection method involves measuring the energy consumption and cooling efficiency of both systems. Testing is carried out in various environmental conditions which include variations in temperature, humidity, and other operational conditions that can affect the performance of each system. The research results show a comparison of COP between air conditioning systems that use air and water condensation. The findings show that systems using air condensation have a lower COP, namely 2.24, compared to systems using water condensation with a value of 2.53 in a certain range of conditions. The efficiency of both systems is also influenced by certain environmental factors, but the efficiency value for condensation with air remains lower with a value of 56.92, while with water condensation with a value of 65.10, this gives an indication that condensation using water is better in the air conditioning system in cars. The conclusion of this research is that both condensation methods have their respective advantages and disadvantages in terms of efficiency and performance.

BIS Energy and EngineeringVol. 1
Sepuluh Nopember Institute of Technology (ID), State University of Padang (ID), Universitas Pgri Banyuwangi (ID)
Universitas Negeri Padang
Openalex Percentile: Top 48%
Refrigeration and Air Conditioning Technologies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.