Acquisition Of Size-Specific Dose Estimates For Abdominal Computed Tomography Examination In Nigeria: A Preliminary Study Using A Water Equivalent Diameter

Background Size-specific dose estimates is an important metric for personalizing dose measurements during abdominal computed tomography (CT) examination. This study aimed to establish patient size-specific dose data as a guide for dose monitoring of abdominal computed tomography examinations among Nigerians. Methods Abdominal CT images of adult subjects obtained from two CT scanners - a light speed VCT –ZTe; (GE Healthcare) 16 – Slice and a Brivo CT 385 series; (GC Healthcare) 16-slice scanners were used in the study. The estimated computed tomography dose index volume (CTDIvol) and dose length product (DLP) were extracted from the CT dose report on the patients’ electronic Image folders. The effective size of the abdomen was obtained by using electronic caliper on the scanner console to measure the anterior-posterior and lateral dimensions at the level of the widest diameter on the image. With Table1A from the AAPM report 220, conversion factors were determined for a total of 264 abdominal CT images. The corresponding conversion factor was multiplied by the CTDIvol to obtain the size specific dose estimates (SSDE). The relationships between effective diameter (ED), CTDIVOL and age on SSDE were analyzed using minitab statistical software version 17. Results The mean CTDlvol was 6.94+ 1.63mGy, while SSDE was 9.76 + 2.56mGy. The SSDE decreased significantly with effective diameter, and increased significantly with the CTDI vol. The effective diameter measured between 8.72.90 and 37.70cm. Conclusion The study concludes that the CTDvol and patient’s abdominal size are determinant factors in the development of a size-specific radiation protection protocol and optimization of patient dose during abdominal CT examinations based on scanner output.

Authors

Publication Details

Journal
Global Journal of Pure and Applied Science
Published
2025-02-07
DOI
https://doi.org/10.4314/gjpas.v31i1.10
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Acquisition Of Size-Specific Dose Estimates For Abdominal Computed Tomography Examination In Nigeria: A Preliminary Study Using A Water Equivalent Diameter

Akpama E. Egong, Akwa Egom Erim, Bassey Eyo Archibong, Blessing Samuel Ibe et al.
1 links
Global Journal of Pure and Applied Science
Radiation Dose and Imaging
article

Acquisition Of Size-Specific Dose Estimates For Abdominal Computed Tomography Examination In Nigeria: A Preliminary Study Using A Water Equivalent Diameter

Akpama E. Egong, Akwa Egom Erim, Bassey Eyo Archibong, Blessing Samuel Ibe, NO Egbe, Uchenna Eusebius Dike, Ekaete Vincent Ukpong, Andrew Ijever Wueseter
article en

Abstract

Background Size-specific dose estimates is an important metric for personalizing dose measurements during abdominal computed tomography (CT) examination. This study aimed to establish patient size-specific dose data as a guide for dose monitoring of abdominal computed tomography examinations among Nigerians. Methods Abdominal CT images of adult subjects obtained from two CT scanners - a light speed VCT –ZTe; (GE Healthcare) 16 – Slice and a Brivo CT 385 series; (GC Healthcare) 16-slice scanners were used in the study. The estimated computed tomography dose index volume (CTDIvol) and dose length product (DLP) were extracted from the CT dose report on the patients’ electronic Image folders. The effective size of the abdomen was obtained by using electronic caliper on the scanner console to measure the anterior-posterior and lateral dimensions at the level of the widest diameter on the image. With Table1A from the AAPM report 220, conversion factors were determined for a total of 264 abdominal CT images. The corresponding conversion factor was multiplied by the CTDIvol to obtain the size specific dose estimates (SSDE). The relationships between effective diameter (ED), CTDIVOL and age on SSDE were analyzed using minitab statistical software version 17. Results The mean CTDlvol was 6.94+ 1.63mGy, while SSDE was 9.76 + 2.56mGy. The SSDE decreased significantly with effective diameter, and increased significantly with the CTDI vol. The effective diameter measured between 8.72.90 and 37.70cm. Conclusion The study concludes that the CTDvol and patient’s abdominal size are determinant factors in the development of a size-specific radiation protection protocol and optimization of patient dose during abdominal CT examinations based on scanner output.

Global Journal of Pure and Applied ScienceVol. 31(1)
Openalex Percentile: Top 96%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.