Incorrectly Charted Operating Rooms, With Resulting Overlapping Times, Corrected Using Meta-Data From Monitors Transmitting Pulse Oximetry Measurements

Recorded operating rooms (ORs) in electronic health records can differ from the actual anesthetizing locations. A retrospective cohort of cases revealed a 40% (846/2123) room location error rate in the obstetrical (OB) suite compared to 0.03% (18/56,044) in 3 large surgical suites. Using meta-data providing physical locations of monitors transmitting pulse oximetry measurements and technicians' manual logs of replacement monitors, all actual ORs of the cases were determined. Simply identifying listed overlaps of cases in the same OR to identify potential location errors was insufficient for OB because surgical cases were infrequently ongoing simultaneously. We recommend overlap checking by suite.

Authors

Institutions

Publication Details

Journal
A&A Practice
Published
2025-02-01
DOI
https://doi.org/10.1213/xaa.0000000000001917
Primary Topic
Cardiac, Anesthesia and Surgical Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Incorrectly Charted Operating Rooms, With Resulting Overlapping Times, Corrected Using Meta-Data From Monitors Transmitting Pulse Oximetry Measurements

Unyime S. Ituk, Franklin Dexter, Richard H. Epstein, Anil A. Marian et al.
A&A Practice
Cardiac, Anesthesia and Surgical Outcomes
article

Incorrectly Charted Operating Rooms, With Resulting Overlapping Times, Corrected Using Meta-Data From Monitors Transmitting Pulse Oximetry Measurements

Unyime S. Ituk, Franklin Dexter, Richard H. Epstein, Anil A. Marian, Michael G. Pomeroy
article en

Abstract

Recorded operating rooms (ORs) in electronic health records can differ from the actual anesthetizing locations. A retrospective cohort of cases revealed a 40% (846/2123) room location error rate in the obstetrical (OB) suite compared to 0.03% (18/56,044) in 3 large surgical suites. Using meta-data providing physical locations of monitors transmitting pulse oximetry measurements and technicians' manual logs of replacement monitors, all actual ORs of the cases were determined. Simply identifying listed overlaps of cases in the same OR to identify potential location errors was insufficient for OB because surgical cases were infrequently ongoing simultaneously. We recommend overlap checking by suite.

A&A PracticeVol. 19(2)
University of Iowa (US), University of Miami (US)
Openalex Percentile: Top 95%
Cardiac, Anesthesia and Surgical Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.