A Simple, Cost‐Effective Microfluidic Device Using a <scp>3D</scp> Cross‐Flow T‐Junction for Producing Decellularized Extracellular Matrix‐Derived Microcarriers

Cell therapies using human mesenchymal stromal cells (MSCs) are promising for a wide variety of clinical applications. However, broad-scale clinical translation is limited by conventional culture methods for MSC expansion within 2D tissue-culture flasks. MSC expansion on ECM-derived microcarriers within stirred bioreactor systems offers a promising approach to support MSC growth. Previously, our team established methods for fabricating ECM-derived microcarriers from a variety of decellularized tissue sources using electrospraying techniques. However, these microcarriers are relatively large and have a broad size distribution, which may limit their utility. Smaller and more uniform microcarriers may be favorable for MSC growth within bioreactors and have greater potential to serve as a minimally invasive injectable cell delivery platform. To address these limitations, the current project focused on the development of a new microfluidic-based approach enabling both uniform and small microcarrier production. Using a novel, modified 3D T-junction design, we successfully generated microcarriers using human decellularized adipose tissue (DAT) as the ECM source. Our new cost-effective device produced microbeads that were small and monodisperse, at a range of flow rate combinations and with high production rates. Photo-crosslinking using rose bengal allowed for the generation of microcarriers that retained their shape and could withstand rehydration, with a mean diameter of 196 ± 47 μm. Following methods optimization and microcarrier characterization, in vitro studies confirmed that the new microcarriers supported human adipose-derived stromal cell (hASC) attachment and growth, as well as ECM production, across 14 days within spinner flask bioreactors. Overall, this study demonstrates the feasibility of using our novel, cost-effective, and reusable microfluidics device to generate cell-supportive microcarriers comprised exclusively of ECM that show promise as an MSC expansion platform.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part A
Published
2025-02-01
DOI
https://doi.org/10.1002/jbm.a.37873
Citations
2
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
1.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Simple, Cost‐Effective Microfluidic Device Using a 3D Cross‐Flow T‐Junction for Producing Decellularized Extracellular Matrix‐Derived Microcarriers

G. Bischof, Farah Kamar, Tamie L. Poepping, Lauren E. Flynn et al.
2 citations
Journal of Biomedical Materials Research Part A
3D Printing in Biomedical Research
1.35
article

A Simple, Cost‐Effective Microfluidic Device Using a 3D Cross‐Flow T‐Junction for Producing Decellularized Extracellular Matrix‐Derived Microcarriers

G. Bischof, Farah Kamar, Tamie L. Poepping, Lauren E. Flynn, Anorin Ali, John R. de Bruyn, C. Gillis
article en
2 citations

Abstract

Cell therapies using human mesenchymal stromal cells (MSCs) are promising for a wide variety of clinical applications. However, broad-scale clinical translation is limited by conventional culture methods for MSC expansion within 2D tissue-culture flasks. MSC expansion on ECM-derived microcarriers within stirred bioreactor systems offers a promising approach to support MSC growth. Previously, our team established methods for fabricating ECM-derived microcarriers from a variety of decellularized tissue sources using electrospraying techniques. However, these microcarriers are relatively large and have a broad size distribution, which may limit their utility. Smaller and more uniform microcarriers may be favorable for MSC growth within bioreactors and have greater potential to serve as a minimally invasive injectable cell delivery platform. To address these limitations, the current project focused on the development of a new microfluidic-based approach enabling both uniform and small microcarrier production. Using a novel, modified 3D T-junction design, we successfully generated microcarriers using human decellularized adipose tissue (DAT) as the ECM source. Our new cost-effective device produced microbeads that were small and monodisperse, at a range of flow rate combinations and with high production rates. Photo-crosslinking using rose bengal allowed for the generation of microcarriers that retained their shape and could withstand rehydration, with a mean diameter of 196 ± 47 μm. Following methods optimization and microcarrier characterization, in vitro studies confirmed that the new microcarriers supported human adipose-derived stromal cell (hASC) attachment and growth, as well as ECM production, across 14 days within spinner flask bioreactors. Overall, this study demonstrates the feasibility of using our novel, cost-effective, and reusable microfluidics device to generate cell-supportive microcarriers comprised exclusively of ECM that show promise as an MSC expansion platform.

Journal of Biomedical Materials Research Part AVol. 113(2)
Western University (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 22%
3D Printing in Biomedical Research
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.