High-temporal-resolution dynamic PET imaging based on a kinetic-induced voxel filter

<i>Objective</i>. Dynamic positron emission tomography (dPET) is an important molecular imaging technology that is used for the clinical diagnosis, staging, and treatment of various human cancers. Higher temporal imaging resolutions are desired for the early stages of radioactive tracer metabolism. However, images reconstructed from raw data with shorter frame durations have lower image signal-to-noise ratios (SNRs) and unexpected spatial resolutions.<i>Approach</i>. To address these issues, this paper proposes a kinetic-induced voxel filtering technique for processing noisy and distorted dPET images. This method extracts the inherent motion information contained in the target PET image and effectively uses this information to construct an image filter for each PET image frame. To ensure that the filtered image remains undistorted, we integrate and reorganize the information from each frame along the temporal dimension. In addition, our method applies repeated filtering operations to the image to produce optimal denoising results.<i>Main results</i>. The effectiveness of the proposed method is validated on both simulated and clinical dPET data, with quantitative evaluations of dynamic images and pharmacokinetic parameter maps calculated via the peak SNR and mean structural similarity index measure. Compared with the state-of-the-art methods, our method achieves superior results in both qualitative and quantitative imaging scenarios.<i>Significance</i>. It exhibits commendable performance and high interpretability and is demonstrated to be both effective and feasible in high-temporal-resolution dynamic PET imaging tasks.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-02-13
DOI
https://doi.org/10.1088/1361-6560/adae4e
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-temporal-resolution dynamic PET imaging based on a kinetic-induced voxel filter

Zhaoping Cheng, Lingxin Chen, Hairong Zheng, Zhanli Hu et al.
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
article

High-temporal-resolution dynamic PET imaging based on a kinetic-induced voxel filter

Zhaoping Cheng, Lingxin Chen, Hairong Zheng, Zhanli Hu, Zhi‐Feng Pang, Liwen Fu, Yongfeng Yang, Yanhua Duan, Dong Liang, Zixiang Chen
article en

Abstract

<i>Objective</i>. Dynamic positron emission tomography (dPET) is an important molecular imaging technology that is used for the clinical diagnosis, staging, and treatment of various human cancers. Higher temporal imaging resolutions are desired for the early stages of radioactive tracer metabolism. However, images reconstructed from raw data with shorter frame durations have lower image signal-to-noise ratios (SNRs) and unexpected spatial resolutions.<i>Approach</i>. To address these issues, this paper proposes a kinetic-induced voxel filtering technique for processing noisy and distorted dPET images. This method extracts the inherent motion information contained in the target PET image and effectively uses this information to construct an image filter for each PET image frame. To ensure that the filtered image remains undistorted, we integrate and reorganize the information from each frame along the temporal dimension. In addition, our method applies repeated filtering operations to the image to produce optimal denoising results.<i>Main results</i>. The effectiveness of the proposed method is validated on both simulated and clinical dPET data, with quantitative evaluations of dynamic images and pharmacokinetic parameter maps calculated via the peak SNR and mean structural similarity index measure. Compared with the state-of-the-art methods, our method achieves superior results in both qualitative and quantitative imaging scenarios.<i>Significance</i>. It exhibits commendable performance and high interpretability and is demonstrated to be both effective and feasible in high-temporal-resolution dynamic PET imaging tasks.

Physics in Medicine and BiologyVol. 70(4)
Henan University (CN), Shenzhen Institutes of Advanced Technology (CN), First Affiliated Hospital of Jinan University (CN), Shandong First Medical University (CN)
National Natural Science Foundation of China, Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Basic and Applied Basic Research Foundation of Guangdong Province
Good health and well-being
Openalex Percentile: Top 96%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.