Experimental investigation on gas permeability characteristics and durability aspects of concrete with construction joint

Construction joint is a weak point for reinforced concrete structure because the interface at construction joint does not behavior as strongly as simultaneously placed concrete matrix. The property of construction joint is critical for infrastructures if the structures need to prevent leakage of hazardous substances or require longer service life. However, the knowledge gap on the performance of construction joint, especially on the evaluation of gas permeability and durability aspects of concrete, still exists. This study was designed to address this knowledge gap by performing experimental investigation on mechanical property, gas permeability, chloride ion penetration, and carbonation of concrete with construction joint. Microstructural observation around the construction joint was performed, and the effect of gauze used to reinforce construction joint was evaluated. According to experimental results, the presence of construction joint decreased the split tensile strength of the concrete. The effect of construction joint on compressive strength and elastic modulus was unclear, but all failures of concrete with construction joints occurred through the interface at construction joint, indicating that splitting stress was generated under compression and split tension. As expected, the gas permeability of concrete with a construction joint was higher than that of concrete without one. Depths of chloride penetration and carbonation were higher through the construction joint than through the concrete matrix. It was found that the presence of gauze did not provide any positive effects on properties of concrete with construction joint. • Analysis of the mechanical properties and gas permeability based on the presence and method of concrete joints • Analysis of the effect of construction joints on chloride penetration and carbonation in concrete. • Analysis of the fracture morphology and joint surface of concrete with construction joints.

Authors

Institutions

Publication Details

Journal
Case Studies in Construction Materials
Published
2025-02-13
DOI
https://doi.org/10.1016/j.cscm.2025.e04399
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation on gas permeability characteristics and durability aspects of concrete with construction joint

Eun-A Seo, Do-Gyeum Kim, Chul-Woo Chung, Ho Jae Lee et al.
Case Studies in Construction Materials
Concrete and Cement Materials Research
article

Experimental investigation on gas permeability characteristics and durability aspects of concrete with construction joint

Eun-A Seo, Do-Gyeum Kim, Chul-Woo Chung, Ho Jae Lee, Ji-Hyun Kim, Y.‐J. Lee
article en

Abstract

Construction joint is a weak point for reinforced concrete structure because the interface at construction joint does not behavior as strongly as simultaneously placed concrete matrix. The property of construction joint is critical for infrastructures if the structures need to prevent leakage of hazardous substances or require longer service life. However, the knowledge gap on the performance of construction joint, especially on the evaluation of gas permeability and durability aspects of concrete, still exists. This study was designed to address this knowledge gap by performing experimental investigation on mechanical property, gas permeability, chloride ion penetration, and carbonation of concrete with construction joint. Microstructural observation around the construction joint was performed, and the effect of gauze used to reinforce construction joint was evaluated. According to experimental results, the presence of construction joint decreased the split tensile strength of the concrete. The effect of construction joint on compressive strength and elastic modulus was unclear, but all failures of concrete with construction joints occurred through the interface at construction joint, indicating that splitting stress was generated under compression and split tension. As expected, the gas permeability of concrete with a construction joint was higher than that of concrete without one. Depths of chloride penetration and carbonation were higher through the construction joint than through the concrete matrix. It was found that the presence of gauze did not provide any positive effects on properties of concrete with construction joint. • Analysis of the mechanical properties and gas permeability based on the presence and method of concrete joints • Analysis of the effect of construction joints on chloride penetration and carbonation in concrete. • Analysis of the fracture morphology and joint surface of concrete with construction joints.

Case Studies in Construction MaterialsVol. 22
Korea Institute of Civil Engineering and Building Technology (KR), Pukyong National University (KR)
Sustainable cities and communities
Openalex Percentile: Top 97%
Concrete and Cement Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.