INVESTIGATION OF THE THERMAL POTENTIAL OF THE AIR IN THE OVERHEAD SPACE OF A GLASS FURNACE

The purpose of the work is to determine the thermal potential of the air of the overhead space of the glass furnace, heated at the expense of heat losses through the refractory masonry of the furnace and the open part of the gas duct of the recuperator, diverting combustion products from the flame space of the furnace and the search for directions of possible use of thermal energy. It was determined that the losses with the air leaving the building are 1.057 MW, or 10 % of the fuel consumption in the unit, the average air temperature is 63°C. As proposals the possibility of heat recovery of low-potential RER is presented, which can be effectively used for drying of raw materials at the site of preparation of raw components to the process of charge making. Calculation of heat content of air flow shows that drying of material can be provided at air flow rate of 3-5 m3/s.

Authors

Institutions

Publication Details

Journal
Energy Systems
Published
2024-12-25
DOI
https://doi.org/10.34031/es.2024.3.004
Primary Topic
Mechanical and Thermal Properties Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

INVESTIGATION OF THE THERMAL POTENTIAL OF THE AIR IN THE OVERHEAD SPACE OF A GLASS FURNACE

Д. А. Плотников, V. Onischuk, Anastasia Shakhova
Energy Systems
Mechanical and Thermal Properties Analysis
article

INVESTIGATION OF THE THERMAL POTENTIAL OF THE AIR IN THE OVERHEAD SPACE OF A GLASS FURNACE

Д. А. Плотников, V. Onischuk, Anastasia Shakhova
article en

Abstract

The purpose of the work is to determine the thermal potential of the air of the overhead space of the glass furnace, heated at the expense of heat losses through the refractory masonry of the furnace and the open part of the gas duct of the recuperator, diverting combustion products from the flame space of the furnace and the search for directions of possible use of thermal energy. It was determined that the losses with the air leaving the building are 1.057 MW, or 10 % of the fuel consumption in the unit, the average air temperature is 63°C. As proposals the possibility of heat recovery of low-potential RER is presented, which can be effectively used for drying of raw materials at the site of preparation of raw components to the process of charge making. Calculation of heat content of air flow shows that drying of material can be provided at air flow rate of 3-5 m3/s.

Energy SystemsVol. 9(3)
Belgorod State Technological University (RU)
Openalex Percentile: Top 73%
Mechanical and Thermal Properties Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

INVESTIGATION OF THE THERMAL POTENTIAL OF THE AIR IN THE OVERHEAD SPACE OF A GLASS FURNACE — Д. А. Плотников, V. Onischuk, et al. · Energy Systems (2024) | TGRS Research Map | TGRS