Applying A-PTV to RBC suspension flows

Abstract In strongly confined flow geometries, red blood cells migrate normal to the flow direction, thereby altering the flow rheology of blood. Direct optical measurements can help to gain an improved understanding of these migration processes. In the present study, we demonstrate that astigmatism particle tracking velocimetry is a suitable 3D-particle tracking method that allows to directly measure both 3D concentration and velocity distributions of red blood cells in a flow. Red blood cells assume a non-spherical shape; therefore, the influence of their orientation on the reconstruction of the out-of-plane particle position is evaluated through a ray tracing approach of synthetic, astigmatic images. While for noise-free images, the resulting absolute out-of-plane reconstruction error $$\sigma _z$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mi>σ</mml:mi> <mml:mi>z</mml:mi> </mml:msub> </mml:math> is small for different red blood cell orientations ( $$\sigma _z$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mi>σ</mml:mi> <mml:mi>z</mml:mi> </mml:msub> </mml:math> = 0.98 $$\upmu \text {m}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mi>μ</mml:mi> <mml:mtext>m</mml:mtext> </mml:mrow> </mml:math> ), it triples for experimentally relevant signal-to-noise ratios (SNR = 1.2). Reconstruction errors are compared to those of spherical particles. Overall, both the red blood cell orientation and the increase in signal-to-noise ratio induce similar out-of-plane reconstruction error values. Experimental analyses are also performed using both a red blood cell suspension system and a refractive index-matched suspension system of identical volume fraction ( $${1.5\,\mathrm{\%}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>1.5</mml:mn> <mml:mspace/> <mml:mo>%</mml:mo> </mml:mrow> </mml:math> ). Comparing results from the red blood cell suspension flow with those of the particulate suspension under identical parameters for volume fraction, particle Reynolds number, and bulk Reynolds number, a similarity in lateral migration behavior is observed under the given conditions. The results indicate that the absolute out-of-plane reconstruction error in the red blood cell suspension system ( $$\sigma _z = {4.50\,\mathrm{{\upmu \text {m}}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub> <mml:mi>σ</mml:mi> <mml:mi>z</mml:mi> </mml:msub> <mml:mo>=</mml:mo> <mml:mrow> <mml:mn>4.50</mml:mn> <mml:mspace/> <mml:mrow> <mml:mi>μ</mml:mi> <mml:mtext>m</mml:mtext> </mml:mrow> </mml:mrow> </mml:mrow> </mml:math> ) is approximately 1.5 times larger compared to the refractive index-matched system. Graphical Abstract

Authors

Institutions

Publication Details

Journal
Experiments in Fluids
Published
2025-02-13
DOI
https://doi.org/10.1007/s00348-025-03975-5
Primary Topic
Lattice Boltzmann Simulation Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Applying A-PTV to RBC suspension flows

T. Werner, Ang Sun, Benjamin Torner, Jeanette Hussong et al.
3 links
Experiments in Fluids
Lattice Boltzmann Simulation Studies
article

Applying A-PTV to RBC suspension flows

T. Werner, Ang Sun, Benjamin Torner, Jeanette Hussong, Frank–Hendrik Wurm, Finn Knüppel
article en

Abstract

Abstract In strongly confined flow geometries, red blood cells migrate normal to the flow direction, thereby altering the flow rheology of blood. Direct optical measurements can help to gain an improved understanding of these migration processes. In the present study, we demonstrate that astigmatism particle tracking velocimetry is a suitable 3D-particle tracking method that allows to directly measure both 3D concentration and velocity distributions of red blood cells in a flow. Red blood cells assume a non-spherical shape; therefore, the influence of their orientation on the reconstruction of the out-of-plane particle position is evaluated through a ray tracing approach of synthetic, astigmatic images. While for noise-free images, the resulting absolute out-of-plane reconstruction error $$\sigma _z$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mi>σ</mml:mi> <mml:mi>z</mml:mi> </mml:msub> </mml:math> is small for different red blood cell orientations ( $$\sigma _z$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mi>σ</mml:mi> <mml:mi>z</mml:mi> </mml:msub> </mml:math> = 0.98 $$\upmu \text {m}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mi>μ</mml:mi> <mml:mtext>m</mml:mtext> </mml:mrow> </mml:math> ), it triples for experimentally relevant signal-to-noise ratios (SNR = 1.2). Reconstruction errors are compared to those of spherical particles. Overall, both the red blood cell orientation and the increase in signal-to-noise ratio induce similar out-of-plane reconstruction error values. Experimental analyses are also performed using both a red blood cell suspension system and a refractive index-matched suspension system of identical volume fraction ( $${1.5\,\mathrm{\%}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>1.5</mml:mn> <mml:mspace/> <mml:mo>%</mml:mo> </mml:mrow> </mml:math> ). Comparing results from the red blood cell suspension flow with those of the particulate suspension under identical parameters for volume fraction, particle Reynolds number, and bulk Reynolds number, a similarity in lateral migration behavior is observed under the given conditions. The results indicate that the absolute out-of-plane reconstruction error in the red blood cell suspension system ( $$\sigma _z = {4.50\,\mathrm{{\upmu \text {m}}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:msub> <mml:mi>σ</mml:mi> <mml:mi>z</mml:mi> </mml:msub> <mml:mo>=</mml:mo> <mml:mrow> <mml:mn>4.50</mml:mn> <mml:mspace/> <mml:mrow> <mml:mi>μ</mml:mi> <mml:mtext>m</mml:mtext> </mml:mrow> </mml:mrow> </mml:mrow> </mml:math> ) is approximately 1.5 times larger compared to the refractive index-matched system. Graphical Abstract

Experiments in FluidsVol. 66(3)
Technische Universität Darmstadt (DE), University of Rostock (DE)
Deutsche Forschungsgemeinschaft, Technische Universität Darmstadt, LOEWE-Zentrum für Translationale Medizin und Pharmakologie
Openalex Percentile: Top 97%
Lattice Boltzmann Simulation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.