Significance of Nonlinearity Consideration in Finite Element Analysis for Preclinical Strength Assessment of Extramedullary Femur Plates

Abstract Accurate finite element (FE)-based evaluations demand realistic modeling of the bone-implant construct. For this, considering nonlinearity in the FE model sometimes becomes essential. Human femora exhibit nonlinear mechanical behavior, which could be attributed to material, large deformation, and boundary conditions. The nonlinearity due to material is specified as material nonlinearity, while due to large deformation or boundary conditions is specified as geometric nonlinearity. The objective of this study is to comprehend the importance of incorporating nonlinearity into FE analyses of extramedullary plates used to treat proximal femoral fractures. Two extramedullary implants—one proximal femoral locking plate (PFLP) and another variable angle-dynamic hip screw (VA-DHS)—were fixated with a femur analog having a simulated intertrochanteric fracture. The constructs were analyzed dynamically for normal walking gait activity and sideways fall scenarios. The analyses were carried out by considering both geometric as well as comprehensive (geometric and material) nonlinearity, and the same were compared with the results from linear models. The results obtained from FE analyses of intact and implanted constructs were validated from in vitro experimental data and FE analysis data reported in previous studies. The investigation revealed that a comprehensive nonlinear analysis, considering both geometric and material factors, can minimize the error percentage to less than 5% while comparing with the data obtained from the experimental approach. The PFLP implant was found to impart higher stiffness (∼30%) as compared to the VA-DHS implant under both load cases of walking and sideways fall.

Authors

Institutions

Publication Details

Journal
Journal of Engineering and Science in Medical Diagnostics and Therapy
Published
2025-02-13
DOI
https://doi.org/10.1115/1.4067893
Primary Topic
Hip disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Significance of Nonlinearity Consideration in Finite Element Analysis for Preclinical Strength Assessment of Extramedullary Femur Plates

Neeraj Kumar, Souptick Chanda, Pratik Nag
Journal of Engineering and Science in Medical Diagnostics and Therapy
Hip disorders and treatments
article

Significance of Nonlinearity Consideration in Finite Element Analysis for Preclinical Strength Assessment of Extramedullary Femur Plates

Neeraj Kumar, Souptick Chanda, Pratik Nag
article en

Abstract

Abstract Accurate finite element (FE)-based evaluations demand realistic modeling of the bone-implant construct. For this, considering nonlinearity in the FE model sometimes becomes essential. Human femora exhibit nonlinear mechanical behavior, which could be attributed to material, large deformation, and boundary conditions. The nonlinearity due to material is specified as material nonlinearity, while due to large deformation or boundary conditions is specified as geometric nonlinearity. The objective of this study is to comprehend the importance of incorporating nonlinearity into FE analyses of extramedullary plates used to treat proximal femoral fractures. Two extramedullary implants—one proximal femoral locking plate (PFLP) and another variable angle-dynamic hip screw (VA-DHS)—were fixated with a femur analog having a simulated intertrochanteric fracture. The constructs were analyzed dynamically for normal walking gait activity and sideways fall scenarios. The analyses were carried out by considering both geometric as well as comprehensive (geometric and material) nonlinearity, and the same were compared with the results from linear models. The results obtained from FE analyses of intact and implanted constructs were validated from in vitro experimental data and FE analysis data reported in previous studies. The investigation revealed that a comprehensive nonlinear analysis, considering both geometric and material factors, can minimize the error percentage to less than 5% while comparing with the data obtained from the experimental approach. The PFLP implant was found to impart higher stiffness (∼30%) as compared to the VA-DHS implant under both load cases of walking and sideways fall.

Journal of Engineering and Science in Medical Diagnostics and TherapyVol. 8(3)
Indian Institute of Technology Guwahati (IN), Indian Institute of Technology Delhi (IN)
Openalex Percentile: Top 95%
Hip disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.