Design and behaviour of moment resisting precast concrete connections with cast-in shear fasteners

The paper proposes a novel design procedure for an innovative connector that provides flexural continuity between ribbed precast concrete flooring units. The innovation was driven by the goal of rapid onsite assembly which precluded the use of structural toppings, complex in-situ stitching of projecting bars or onsite welding. Assembly on site is a simple process of bringing the precast elements together on temporary supports and grouting the prefabricated steel connectors into well-voids cast into the member ends. The benefits of the developed connection have been successfully demonstrated within a number of full-scale prototypes. Due to the novel and unconventional form of the proposed connector, physical testing was crucial to provide an in-depth understanding of its response characteristics under serviceability and ultimate loading conditions. Towards this end, three full size specimens were tested to failure under four-point bending. The outcomes of these experiments are used to validate 3-D high-fidelity nonlinear finite element analysis models. These are finally used in a wide-ranging study to demonstrate the applicability of the proposed design procedure for this novel precast concrete connection system. • Design procedure for a novel connector that provides flexural continuity between precast concrete flooring units. • Connector allows rapid assembly of next-generation precast concrete building systems without structural toppings. • Structure frame on-site construction programme reduced by 50–70 %, and overall building construction programmes by 20–30 %. • Three laboratory tests and NLFEA are used to justify the assumptions made in the proposed design method.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2025-02-13
DOI
https://doi.org/10.1016/j.engstruct.2025.119886
Citations
3
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
3.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and behaviour of moment resisting precast concrete connections with cast-in shear fasteners

Robert Lars Vollum, Glen Rust, B.A. Izzuddin, Jean Paul Vella et al.
3 citations
Engineering Structures
Structural Behavior of Reinforced Concrete
3.02
article

Design and behaviour of moment resisting precast concrete connections with cast-in shear fasteners

Robert Lars Vollum, Glen Rust, B.A. Izzuddin, Jean Paul Vella, Kamil Riedel
article en
3 citations

Abstract

The paper proposes a novel design procedure for an innovative connector that provides flexural continuity between ribbed precast concrete flooring units. The innovation was driven by the goal of rapid onsite assembly which precluded the use of structural toppings, complex in-situ stitching of projecting bars or onsite welding. Assembly on site is a simple process of bringing the precast elements together on temporary supports and grouting the prefabricated steel connectors into well-voids cast into the member ends. The benefits of the developed connection have been successfully demonstrated within a number of full-scale prototypes. Due to the novel and unconventional form of the proposed connector, physical testing was crucial to provide an in-depth understanding of its response characteristics under serviceability and ultimate loading conditions. Towards this end, three full size specimens were tested to failure under four-point bending. The outcomes of these experiments are used to validate 3-D high-fidelity nonlinear finite element analysis models. These are finally used in a wide-ranging study to demonstrate the applicability of the proposed design procedure for this novel precast concrete connection system. • Design procedure for a novel connector that provides flexural continuity between precast concrete flooring units. • Connector allows rapid assembly of next-generation precast concrete building systems without structural toppings. • Structure frame on-site construction programme reduced by 50–70 %, and overall building construction programmes by 20–30 %. • Three laboratory tests and NLFEA are used to justify the assumptions made in the proposed design method.

Engineering StructuresVol. 330
Laing O'Rourke (United Kingdom) (GB), Imperial College London (GB)
Engineering and Physical Sciences Research Council
Sustainable cities and communities
Openalex Percentile: Top 11%
Structural Behavior of Reinforced Concrete
3.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.