Validation of a Multi-Channel Ambient Sensor to Measure Vital Signs in Patients Within the Ward and at Home

Hospitalised, unwell patients have vital signs such as heart rate (HR), oxygen saturation (SpO<sub>2</sub>) and temperature measured multiple times a day to detect clinical deterioration and monitor health trajectories. Advancements in contact-free (ambient) sensors (AS) to measure vital signs can help mitigate risks due to skin injury and infection transmission seen in conventional hospital equipment. This prospective, observational clinical study aims to validate vital sign measurements from a multi-channel AS compared to conventional equipment in three cohorts: patients in a hospital ward, patients at home within a Hospital-at-Home service, and healthy volunteers. Data analysis of 571 paired measurements from 29 participants indicates that heart rate measurements via AS were accurate, though they lacked precision, with the clinical agreement range between 6.38 and 6.49 beats per minute. Temperature and oxygen saturation measurements showed less agreement when compared with the reference standard. In conclusion, ambient sensors show promising utility in measuring vital signs, with this study amongst the first of its kind to utilise this in measuring vital signs in hospitalised patient cohorts in both ward and home environments.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-02-13
DOI
https://doi.org/10.3390/s25041149
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of a Multi-Channel Ambient Sensor to Measure Vital Signs in Patients Within the Ward and at Home

Wen Kwang Lim, S. Fu, Sabine Braat, Seok Lim et al.
1 citations
Sensors
Non-Invasive Vital Sign Monitoring
0.67
article

Validation of a Multi-Channel Ambient Sensor to Measure Vital Signs in Patients Within the Ward and at Home

Wen Kwang Lim, S. Fu, Sabine Braat, Seok Lim, Douglas Johnson, Ye Htet Aung, Peixuan Li
article en
1 citations

Abstract

Hospitalised, unwell patients have vital signs such as heart rate (HR), oxygen saturation (SpO<sub>2</sub>) and temperature measured multiple times a day to detect clinical deterioration and monitor health trajectories. Advancements in contact-free (ambient) sensors (AS) to measure vital signs can help mitigate risks due to skin injury and infection transmission seen in conventional hospital equipment. This prospective, observational clinical study aims to validate vital sign measurements from a multi-channel AS compared to conventional equipment in three cohorts: patients in a hospital ward, patients at home within a Hospital-at-Home service, and healthy volunteers. Data analysis of 571 paired measurements from 29 participants indicates that heart rate measurements via AS were accurate, though they lacked precision, with the clinical agreement range between 6.38 and 6.49 beats per minute. Temperature and oxygen saturation measurements showed less agreement when compared with the reference standard. In conclusion, ambient sensors show promising utility in measuring vital signs, with this study amongst the first of its kind to utilise this in measuring vital signs in hospitalised patient cohorts in both ward and home environments.

SensorsVol. 25(4)
The Royal Melbourne Hospital (AU), The University of Melbourne (AU)
Good health and well-being
Openalex Percentile: Top 35%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.