Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator

To increase energy efficiency, heat pump dryers and membrane dryers have been proposed to replace conventional fossil fuel dryers. Both conventional and heat pump dryers require substantial energy for condensing and reheating, while "active" membrane systems require vacuum pumps that are insufficiently developed. Lower temperature dehumidification systems make efficient use of membrane energy recovery ventilators (MERVs) that do not need vacuum pumps, but their high heat losses and lack of vapor selectivity have prevented their use in industrial drying. In this work, we propose an insulating membrane energy recovery ventilator for moisture removal from drying exhaust air, thereby reducing sensible heat loss from the dehumidification process and reheating energy. The second law analysis of the proposed system is carried out and compared with a baseline convective heat pump dryer. Irreversibilities in each component under different ambient temperatures (5-35 °C) and relative humidity (5-95%) are identified. At an ambient temperature of 35 °C, the proposed system substantially reduces sensible heat loss (47-60%) in the dehumidification process, resulting in a large reduction in condenser load (45-50%) compared to the baseline system. The evaporator in the proposed system accounts for up to 59% less irreversibility than the baseline system. A maximum of 24.5% reduction in overall exergy input is also observed. The highest exergy efficiency of 10.2% is obtained at an ambient condition of 35 °C and 5% relative humidity, which is more than twice the efficiency of the baseline system under the same operating condition.

Authors

Institutions

Publication Details

Journal
Entropy
Published
2025-02-13
DOI
https://doi.org/10.3390/e27020197
Citations
2
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator

Md Ashiqur Rahman, Davide Ziviani, David M. Warsinger, Anand Balaraman
2 citations
Entropy
Adsorption and Cooling Systems
1.43
article

Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator

Md Ashiqur Rahman, Davide Ziviani, David M. Warsinger, Anand Balaraman
article en
2 citations

Abstract

To increase energy efficiency, heat pump dryers and membrane dryers have been proposed to replace conventional fossil fuel dryers. Both conventional and heat pump dryers require substantial energy for condensing and reheating, while "active" membrane systems require vacuum pumps that are insufficiently developed. Lower temperature dehumidification systems make efficient use of membrane energy recovery ventilators (MERVs) that do not need vacuum pumps, but their high heat losses and lack of vapor selectivity have prevented their use in industrial drying. In this work, we propose an insulating membrane energy recovery ventilator for moisture removal from drying exhaust air, thereby reducing sensible heat loss from the dehumidification process and reheating energy. The second law analysis of the proposed system is carried out and compared with a baseline convective heat pump dryer. Irreversibilities in each component under different ambient temperatures (5-35 °C) and relative humidity (5-95%) are identified. At an ambient temperature of 35 °C, the proposed system substantially reduces sensible heat loss (47-60%) in the dehumidification process, resulting in a large reduction in condenser load (45-50%) compared to the baseline system. The evaporator in the proposed system accounts for up to 59% less irreversibility than the baseline system. A maximum of 24.5% reduction in overall exergy input is also observed. The highest exergy efficiency of 10.2% is obtained at an ambient condition of 35 °C and 5% relative humidity, which is more than twice the efficiency of the baseline system under the same operating condition.

EntropyVol. 27(2)
Purdue University West Lafayette (US)
U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, Office of Energy Efficiency
Openalex Percentile: Top 22%
Adsorption and Cooling Systems
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator — Md Ashiqur Rahman, Davide Ziviani, et al. · Entropy (2025) | TGRS Research Map | TGRS