Recovering Ammonia as Ammonium Citrate and Ammonium Sulfate from Sludge Digestion Liquors Using Membrane Contactors in a Pilot Plant

Membrane contactors have proved to be effective for recovering ammonia from wastewater by absorbing it into a trapping solution. This study compares the performance of sulfuric acid and citric acid as trapping solutions in a pilot-scale plant for recovering ammonia from sludge digestion liquors using membrane contactors in a liquid-liquid configuration operating at pH 10 and a temperature of 37 °C and using ultrafiltration (UF) technology as pretreatment. The performance of the process using sulfuric acid at a lower pH (9.5) and temperature (30 °C) was also studied, as well as the advantage of including a CO<sub>2</sub>-stripping module in the process. The ammonia elimination efficiency was 88% and 86% when using sulfuric acid and citric acid, respectively. The nitrogen concentration of the produced ammonium sulfate and ammonium citrate reached 23.2 and 14.7 g NH<sub>3</sub>-N·L<sup>-1</sup>, respectively. The ammonia elimination efficiency when using sulfuric acid decreased to 49% when decreasing the pH to 9.5 and to 85% when decreasing the temperature to 31 °C. UF technology was able to reduce the concentration of suspended solids by 90% and the chemical oxygen demand by 37%. However, the UF membranes for the pretreatment and the membrane contactors for ammonia recovery had to be constantly cleaned with acid due to scaling, which significantly increased maintenance efforts. The CO<sub>2</sub>-stripping module reduced the consumption of the caustic soda solution by 23% for increasing the pH level of the treated water. Finally, the specific energy consumption of the plant was 8 kWh·m<sup>-3</sup>.

Authors

Institutions

Publication Details

Journal
Membranes
Published
2025-02-13
DOI
https://doi.org/10.3390/membranes15020062
Citations
2
Primary Topic
Wastewater Treatment and Nitrogen Removal
Type
article
Field-Weighted Citation Impact
1.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Recovering Ammonia as Ammonium Citrate and Ammonium Sulfate from Sludge Digestion Liquors Using Membrane Contactors in a Pilot Plant

Günter E. M. Tovar, Marius Mohr, Susanne Zibek, Ricardo Reyes Alva
2 citations
Membranes
Wastewater Treatment and Nitrogen Removal
1.01
article

Recovering Ammonia as Ammonium Citrate and Ammonium Sulfate from Sludge Digestion Liquors Using Membrane Contactors in a Pilot Plant

Günter E. M. Tovar, Marius Mohr, Susanne Zibek, Ricardo Reyes Alva
article en
2 citations

Abstract

Membrane contactors have proved to be effective for recovering ammonia from wastewater by absorbing it into a trapping solution. This study compares the performance of sulfuric acid and citric acid as trapping solutions in a pilot-scale plant for recovering ammonia from sludge digestion liquors using membrane contactors in a liquid-liquid configuration operating at pH 10 and a temperature of 37 °C and using ultrafiltration (UF) technology as pretreatment. The performance of the process using sulfuric acid at a lower pH (9.5) and temperature (30 °C) was also studied, as well as the advantage of including a CO<sub>2</sub>-stripping module in the process. The ammonia elimination efficiency was 88% and 86% when using sulfuric acid and citric acid, respectively. The nitrogen concentration of the produced ammonium sulfate and ammonium citrate reached 23.2 and 14.7 g NH<sub>3</sub>-N·L<sup>-1</sup>, respectively. The ammonia elimination efficiency when using sulfuric acid decreased to 49% when decreasing the pH to 9.5 and to 85% when decreasing the temperature to 31 °C. UF technology was able to reduce the concentration of suspended solids by 90% and the chemical oxygen demand by 37%. However, the UF membranes for the pretreatment and the membrane contactors for ammonia recovery had to be constantly cleaned with acid due to scaling, which significantly increased maintenance efforts. The CO<sub>2</sub>-stripping module reduced the consumption of the caustic soda solution by 23% for increasing the pH level of the treated water. Finally, the specific energy consumption of the plant was 8 kWh·m<sup>-3</sup>.

MembranesVol. 15(2)
University of Stuttgart (DE), Fraunhofer Institute for Interfacial Engineering and Biotechnology (DE)
European Commission, Fraunhofer-Gesellschaft, Ministry of Environment, European Regional Development Fund
Openalex Percentile: Top 29%
Wastewater Treatment and Nitrogen Removal
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.