Facile Antibody Immobilization on a Redox-Active Thionine-Functionalized Carbon Nanofiber Surface for Rapid Electrochemical Immunosensing of a Bioengineered Malaria Protein Biomarker

Antibodies that target the <i>Plasmodium falciparum</i> histidine-rich protein-II biomarker (<i>Pf</i>HRP-II) are being used in rapid diagnostic tests (RDTs) of malaria. <i>Pf</i>HRP-II levels associated with severe malaria are typically greater than 100 ng mL<sup>-1</sup>. Unfortunately, genetic variations within the <i>Pf</i>HRP-II gene can reduce the reliability of these RDTs by affecting both sensitivity and specificity. In this study, we developed in-house antibodies against conserved C-terminal 105 amino acids of the <i>Pf</i>HRP-II biomarker to enhance malaria diagnosis using an electrochemical immunosensor technique. Unlike conventional electrochemical immunosensor assays, which use solution-phase enzyme-transducer systems like ferricyanide that suffer from poor current sensitivity and false positives, we constructed a heterogeneous electrochemical immunosensor. This sensor employs highly redox-active thionine (Th) immobilized on a carbon nanofiber (CNF)-based chemically modified electrode (CME) platform. The prepared CME was characterized using several physicochemical techniques, revealing that the oxygen-rich functional groups of CNF serve as active sites for effective antibody binding and immunosensing. Sequential modifications were performed using 2 μL volumes of the polyclonal antibody, antigen (<i>Pf</i>HRP-II), bioengineered monoclonal antibody, and horseradish peroxidase-coupled secondary antibody (Ab2HRP), with each step requiring an incubation time of 3-5 min, resulting in a total working time of 30 ± 5 min. The immunosensor demonstrated excellent sensing signals within a range of 250 pg/mL to 100 ng/mL <i>Pf</i>HRP-II, with a high current sensitivity of 0.813 μA/ng mL<sup>-1</sup>. Control experiments with healthy rabbit and human blood serum samples showed no current response, ruling out false positive signals from the assay. For real-time application, high-performance electrochemical immunosensing of rabbit and human blood serum samples spiked with <i>Pf</i>HRP-II was demonstrated with high accuracy.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2025-02-13
DOI
https://doi.org/10.1021/acs.langmuir.4c03620
Citations
3
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
2.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Facile Antibody Immobilization on a Redox-Active Thionine-Functionalized Carbon Nanofiber Surface for Rapid Electrochemical Immunosensing of a Bioengineered Malaria Protein Biomarker

Annamalai Senthil Kumar, N.S. Jayaprakash, Avtar Sain, Sugumar Monisha
3 citations
Langmuir
Advanced biosensing and bioanalysis techniques
2.42
article

Facile Antibody Immobilization on a Redox-Active Thionine-Functionalized Carbon Nanofiber Surface for Rapid Electrochemical Immunosensing of a Bioengineered Malaria Protein Biomarker

Annamalai Senthil Kumar, N.S. Jayaprakash, Avtar Sain, Sugumar Monisha
article en
3 citations

Abstract

Antibodies that target the <i>Plasmodium falciparum</i> histidine-rich protein-II biomarker (<i>Pf</i>HRP-II) are being used in rapid diagnostic tests (RDTs) of malaria. <i>Pf</i>HRP-II levels associated with severe malaria are typically greater than 100 ng mL<sup>-1</sup>. Unfortunately, genetic variations within the <i>Pf</i>HRP-II gene can reduce the reliability of these RDTs by affecting both sensitivity and specificity. In this study, we developed in-house antibodies against conserved C-terminal 105 amino acids of the <i>Pf</i>HRP-II biomarker to enhance malaria diagnosis using an electrochemical immunosensor technique. Unlike conventional electrochemical immunosensor assays, which use solution-phase enzyme-transducer systems like ferricyanide that suffer from poor current sensitivity and false positives, we constructed a heterogeneous electrochemical immunosensor. This sensor employs highly redox-active thionine (Th) immobilized on a carbon nanofiber (CNF)-based chemically modified electrode (CME) platform. The prepared CME was characterized using several physicochemical techniques, revealing that the oxygen-rich functional groups of CNF serve as active sites for effective antibody binding and immunosensing. Sequential modifications were performed using 2 μL volumes of the polyclonal antibody, antigen (<i>Pf</i>HRP-II), bioengineered monoclonal antibody, and horseradish peroxidase-coupled secondary antibody (Ab2HRP), with each step requiring an incubation time of 3-5 min, resulting in a total working time of 30 ± 5 min. The immunosensor demonstrated excellent sensing signals within a range of 250 pg/mL to 100 ng/mL <i>Pf</i>HRP-II, with a high current sensitivity of 0.813 μA/ng mL<sup>-1</sup>. Control experiments with healthy rabbit and human blood serum samples showed no current response, ruling out false positive signals from the assay. For real-time application, high-performance electrochemical immunosensing of rabbit and human blood serum samples spiked with <i>Pf</i>HRP-II was demonstrated with high accuracy.

LangmuirVol. 41(7)
Green Technology (US), Separation Systems (United States) (US), Vellore Institute of Technology University (IN)
Indian Council of Medical Research, Science and Engineering Research Board
Good health and well-being
Openalex Percentile: Top 13%
Advanced biosensing and bioanalysis techniques
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.