Mechanical and fatigue performance of multidirectional functionally graded Ti6Al4V scaffolds produced via laser powder bed fusion for orthopedic implants

• Multidirectional Functionally Graded Ti6Al4V scaffolds for orthopedic implants were fabricated via Laser Powder Bed Fusion. • Gyroid and Primitive lattices exhibited superior mechanical and fatigue properties compared to strut-based lattices. • Gyroid lattice sustained 25 MPa after 10 6 cycles, demonstrating long-term durability under high-cycle fatigue conditions. • Hot Isostatic Pressing and sandblasting, improved structural integrity, removing surface imperfections. • Results support the use of bio-inspired lattice scaffolds orthopedic implants and regenerative medicine applications. Orthopedic implants require porosity gradients to achieve tissue integration and mechanical support. This study presents a novel design of Multidirectional Functionally Graded (MDFG) porous Ti6Al4V scaffolds, fabricated via Laser Powder Bed Fusion (LPBF) to mimic natural bone porosity for orthopedic applications. Four scaffold types were developed: Gyroid and Primitive (sheet-based TPMS) and Kelvin and Voronoi (strut-based lattices). A pore size of 1000 µm was maintained to promote tissue ingrowth, while strut thickness grading (0.3–0.7 mm) enhanced mechanical stability. Quasi-static compression tests showed Young’s moduli of 9.5 GPa (Gyroid) and 9.3 GPa (Primitive), with ultimate strengths of 240 MPa and 190 MPa, respectively. Energy absorption was 47.74 MJ/m 3 for Gyroid and 46.68 MJ/m 3 for Primitive, demonstrating excellent resistance to mechanical failure. Fatigue testing revealed that the Gyroid lattice sustained 25 MPa after one million cycles, highlighting its long-term durability. Fractographic analysis showed that fatigue cracks initiated at surface defects and propagated along strut intersections, providing insights into failure mechanisms. These findings confirm that MDFG scaffolds, particularly Gyroid and Primitive lattices, enhance mechanical robustness and biological compatibility, making them strong candidates for load-bearing orthopedic implants.

Authors

Institutions

Publication Details

Journal
Materials & Design
Published
2025-02-13
DOI
https://doi.org/10.1016/j.matdes.2025.113725
Citations
32
Primary Topic
Additive Manufacturing Materials and Processes
Type
article
Field-Weighted Citation Impact
22.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical and fatigue performance of multidirectional functionally graded Ti6Al4V scaffolds produced via laser powder bed fusion for orthopedic implants

Mika Salmi, Franco Concli, Ragul Gandhi, Lorenzo Pagliari et al.
32 citations
Materials & Design
Additive Manufacturing Materials and Processes
22.83
article

Mechanical and fatigue performance of multidirectional functionally graded Ti6Al4V scaffolds produced via laser powder bed fusion for orthopedic implants

Mika Salmi, Franco Concli, Ragul Gandhi, Lorenzo Pagliari, Björkstrand Roy, Lehto Pauli
article en
32 citations

Abstract

• Multidirectional Functionally Graded Ti6Al4V scaffolds for orthopedic implants were fabricated via Laser Powder Bed Fusion. • Gyroid and Primitive lattices exhibited superior mechanical and fatigue properties compared to strut-based lattices. • Gyroid lattice sustained 25 MPa after 10 6 cycles, demonstrating long-term durability under high-cycle fatigue conditions. • Hot Isostatic Pressing and sandblasting, improved structural integrity, removing surface imperfections. • Results support the use of bio-inspired lattice scaffolds orthopedic implants and regenerative medicine applications. Orthopedic implants require porosity gradients to achieve tissue integration and mechanical support. This study presents a novel design of Multidirectional Functionally Graded (MDFG) porous Ti6Al4V scaffolds, fabricated via Laser Powder Bed Fusion (LPBF) to mimic natural bone porosity for orthopedic applications. Four scaffold types were developed: Gyroid and Primitive (sheet-based TPMS) and Kelvin and Voronoi (strut-based lattices). A pore size of 1000 µm was maintained to promote tissue ingrowth, while strut thickness grading (0.3–0.7 mm) enhanced mechanical stability. Quasi-static compression tests showed Young’s moduli of 9.5 GPa (Gyroid) and 9.3 GPa (Primitive), with ultimate strengths of 240 MPa and 190 MPa, respectively. Energy absorption was 47.74 MJ/m 3 for Gyroid and 46.68 MJ/m 3 for Primitive, demonstrating excellent resistance to mechanical failure. Fatigue testing revealed that the Gyroid lattice sustained 25 MPa after one million cycles, highlighting its long-term durability. Fractographic analysis showed that fatigue cracks initiated at surface defects and propagated along strut intersections, providing insights into failure mechanisms. These findings confirm that MDFG scaffolds, particularly Gyroid and Primitive lattices, enhance mechanical robustness and biological compatibility, making them strong candidates for load-bearing orthopedic implants.

Materials & DesignVol. 251
Free University of Bozen-Bolzano (IT), Aalto University (FI)
Openalex Percentile: Top 0%
Additive Manufacturing Materials and Processes
22.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.