Comparison of dose distribution with and without reflecting heterogeneous boron distribution using 18F-BPA positron emission tomography in boron neutron capture therapy

This study investigated the dosimetric impact of implementing heterogeneous boron distribution into dose evaluations on tumors in BNCT. The study involved 27 patients who underwent <sup>18</sup>F-BPA PET/CT scans. Dose evaluations were performed using various methods reflecting boron concentrations on CT images. The conventional dose evaluations, which reflected uniform boron concentration in blood of 25 ppm and a constant tumor-to-blood (T/B) ratio of 3.5, were compared with individual dose evaluations, which reflected the blood boron concentration and T/B ratio calculated from <sup>18</sup>F-BPA in each patient. The heterogeneous tumoral dose distribution was also compared, revealing the dosimetric impact of the boron distribution calculated from each voxel of <sup>18</sup>F-BPA. The spatial correspondence between <sup>18</sup>F-BPA and dose distribution was compared using metabolic tumor volume (MTV) from <sup>18</sup>F-BPA and isodose volume from the heterogeneous dose distribution. Results showed that the median blood boron concentration and T/B ratio calculated from <sup>18</sup>F-BPA were 25.57 (23.90-27.84) ppm and 3.75 (2.54-4.59), respectively, comparable to those in the conventional dose evaluations. All dose indices in the heterogeneous tumoral dose evaluations were significantly lower than those in the conventional dose evaluations (p < 0.01). However, the spatial correspondence between the <sup>18</sup>F-BPA and the dose distribution was not observed in the dice similarity coefficients of both MTV40-40% isodose volume and MTV50-50% isodose volume. In conclusion, the study confirmed the validity of applying the boron concentration calculated from <sup>18</sup>F-BPA to the dose evaluation for a patient in BNCT. The differences might be associated with non-inter-patient variations of <sup>18</sup>F-BPA, but the conventional dose evaluations mainly focused on the high boron concentration area within the tumor. Furthermore, the discrepancies in the patients were also observed between the <sup>18</sup>F-BPA distribution and the heterogeneous dose distribution. Therefore, this study suggested that the indications for BNCT should consider not only <sup>18</sup>F-BPA but also the dose distributions, which could reflect the heterogeneous tumoral boron distribution.

Authors

Institutions

Publication Details

Journal
Applied Radiation and Isotopes
Published
2025-02-13
DOI
https://doi.org/10.1016/j.apradiso.2025.111720
Citations
2
Primary Topic
Boron Compounds in Chemistry
Type
article
Field-Weighted Citation Impact
2.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of dose distribution with and without reflecting heterogeneous boron distribution using 18F-BPA positron emission tomography in boron neutron capture therapy

Miki Yonemura, Jun Itami, Kana Takahashi, Hiroyuki Okamoto et al.
2 citations
Applied Radiation and Isotopes
Boron Compounds in Chemistry
2.72
article

Comparison of dose distribution with and without reflecting heterogeneous boron distribution using 18F-BPA positron emission tomography in boron neutron capture therapy

Miki Yonemura, Jun Itami, Kana Takahashi, Hiroyuki Okamoto, Hiroshi Igaki, Hironori Kishida, Takahito Chiba, Kimiteru Ito, Yasunori Shuto, Mihiro Takemori, Tetsu Nakaichi, Yuta Kobayashi, Tairo Kashihara, Kouji Kunito, Riki Oshika, Satoshi Nakamura, Hiroki Nakayama, Hiroaki Kurihara, Hideho Endo
article en
2 citations

Abstract

This study investigated the dosimetric impact of implementing heterogeneous boron distribution into dose evaluations on tumors in BNCT. The study involved 27 patients who underwent <sup>18</sup>F-BPA PET/CT scans. Dose evaluations were performed using various methods reflecting boron concentrations on CT images. The conventional dose evaluations, which reflected uniform boron concentration in blood of 25 ppm and a constant tumor-to-blood (T/B) ratio of 3.5, were compared with individual dose evaluations, which reflected the blood boron concentration and T/B ratio calculated from <sup>18</sup>F-BPA in each patient. The heterogeneous tumoral dose distribution was also compared, revealing the dosimetric impact of the boron distribution calculated from each voxel of <sup>18</sup>F-BPA. The spatial correspondence between <sup>18</sup>F-BPA and dose distribution was compared using metabolic tumor volume (MTV) from <sup>18</sup>F-BPA and isodose volume from the heterogeneous dose distribution. Results showed that the median blood boron concentration and T/B ratio calculated from <sup>18</sup>F-BPA were 25.57 (23.90-27.84) ppm and 3.75 (2.54-4.59), respectively, comparable to those in the conventional dose evaluations. All dose indices in the heterogeneous tumoral dose evaluations were significantly lower than those in the conventional dose evaluations (p < 0.01). However, the spatial correspondence between the <sup>18</sup>F-BPA and the dose distribution was not observed in the dice similarity coefficients of both MTV40-40% isodose volume and MTV50-50% isodose volume. In conclusion, the study confirmed the validity of applying the boron concentration calculated from <sup>18</sup>F-BPA to the dose evaluation for a patient in BNCT. The differences might be associated with non-inter-patient variations of <sup>18</sup>F-BPA, but the conventional dose evaluations mainly focused on the high boron concentration area within the tumor. Furthermore, the discrepancies in the patients were also observed between the <sup>18</sup>F-BPA distribution and the heterogeneous dose distribution. Therefore, this study suggested that the indications for BNCT should consider not only <sup>18</sup>F-BPA but also the dose distributions, which could reflect the heterogeneous tumoral boron distribution.

Applied Radiation and IsotopesVol. 219
Kanagawa Prefectural Hospital Organization (JP), National Cancer Centre Japan (JP), National Cancer Center (US), Shinmatsudo Central General Hospital (JP), National Cancer Research Institute (GB), Komazawa University (JP)
Japan Agency for Medical Research and Development, Japan Society for the Promotion of Science London
Openalex Percentile: Top 12%
Boron Compounds in Chemistry
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.