Monitoring Mouse Surface Temperature During Stress with a Thermal Camera: A Low‐Cost Infrared Videography System for Evaluating Murine Metabolism

Energy is required for life, and organisms obtain their energy from fuel sources to enable both anabolic and catabolic processes. Some of this energy is radiated as heat, which can be quantified as a measure of metabolic rate. In some cases, environmental toxicants can alter metabolic energy in undesirable ways, and characterization of new pharmaceuticals can determine the efficacy of desirable metabolic rate manipulation or identify off-target adverse effects. Current methods to directly measure heat production in laboratory mice are expensive, can be laborious, and make it challenging to monitor animals in ways that are multiplexed, robust, and non-invasive. We present a set of protocols for assembling and deploying a simple, low-cost thermal camera to monitor and record thermogenic activity, modified from prior work. Parts used to build this system currently cost approximately $150 USD and, when assembled, can record mouse temperatures as well as ambient cage temperatures up to twice per second for extended periods. By using multiplexed cameras in a diurnal mouse incubator system, the thermogenic capacity of several mice can be simultaneously recorded and graphed. Exogenous agents and genotypes that alter metabolism can be readily identified with this technology. In this set of protocols, we describe the assembly of the thermal video camera device, its use, and related data capture and analysis methods. © 2025 The Author(s). Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1: Assembling thermal camera for thermogenic stress test Basic Protocol 2: In vivo measurement of mouse temperature under different ambient conditions.

Authors

Institutions

Publication Details

Journal
Current Protocols
Published
2025-02-01
DOI
https://doi.org/10.1002/cpz1.70098
Primary Topic
Adipose Tissue and Metabolism
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring Mouse Surface Temperature During Stress with a Thermal Camera: A Low‐Cost Infrared Videography System for Evaluating Murine Metabolism

Matthew D. Lynes, R. R. Reno, Maureen S. Lynes, Michael A. Lynes et al.
Current Protocols
Adipose Tissue and Metabolism
article

Monitoring Mouse Surface Temperature During Stress with a Thermal Camera: A Low‐Cost Infrared Videography System for Evaluating Murine Metabolism

Matthew D. Lynes, R. R. Reno, Maureen S. Lynes, Michael A. Lynes, James Reilly, B. S. Page, Carolina Cora, Wadak Harbi
article en

Abstract

Energy is required for life, and organisms obtain their energy from fuel sources to enable both anabolic and catabolic processes. Some of this energy is radiated as heat, which can be quantified as a measure of metabolic rate. In some cases, environmental toxicants can alter metabolic energy in undesirable ways, and characterization of new pharmaceuticals can determine the efficacy of desirable metabolic rate manipulation or identify off-target adverse effects. Current methods to directly measure heat production in laboratory mice are expensive, can be laborious, and make it challenging to monitor animals in ways that are multiplexed, robust, and non-invasive. We present a set of protocols for assembling and deploying a simple, low-cost thermal camera to monitor and record thermogenic activity, modified from prior work. Parts used to build this system currently cost approximately $150 USD and, when assembled, can record mouse temperatures as well as ambient cage temperatures up to twice per second for extended periods. By using multiplexed cameras in a diurnal mouse incubator system, the thermogenic capacity of several mice can be simultaneously recorded and graphed. Exogenous agents and genotypes that alter metabolism can be readily identified with this technology. In this set of protocols, we describe the assembly of the thermal video camera device, its use, and related data capture and analysis methods. © 2025 The Author(s). Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1: Assembling thermal camera for thermogenic stress test Basic Protocol 2: In vivo measurement of mouse temperature under different ambient conditions.

Current ProtocolsVol. 5(2)
Northeastern University (US), University of Connecticut (US), MaineHealth (US), Accent Therapeutics (United States) (US), University of Maine (US)
National Institutes of Health
Affordable and clean energy
Openalex Percentile: Top 96%
Adipose Tissue and Metabolism
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.