TRUMATCH <sup>TM</sup> Graft Cage—Long Bone as a solution for tibial bone defect in traumatic aseptic non-union: a case report
This case report describes a challenging case of aseptic traumatic non-union of the tibia with a critical-sized defect treated with a novel patient-specific implant in a one-stage procedure. The application of the TRUMATCH<sup>TM</sup> Graft Cage-Long Bone is promising and warrants further investigation in larger, more controlled studies to substantiate our findings.
Authors
- Kostan W. Reisinger
- Maud A. M. Vesseur (ORCID: https://orcid.org/0000-0001-9086-9620)
- Bert Boonen (ORCID: https://orcid.org/0000-0002-1301-4802)
- Raoul van Vugt (ORCID: https://orcid.org/0000-0002-3293-7223)
- Isobel M. Dorling (ORCID: https://orcid.org/0009-0000-4385-993X)
Institutions
- Zuyderland Medisch Centrum (NL)
Publication Details
- Journal
- Acta chirurgica Belgica
- Published
- 2025-02-13
- DOI
- https://doi.org/10.1080/00015458.2025.2467482
- Citations
- 2
- Primary Topic
- Bone fractures and treatments
- Type
- article
- Field-Weighted Citation Impact
- 2.71