Collaboration and Control Strategy for Dual Traction Station Flexible AC Traction Power System during Catenary Faults

In the flexible AC traction power supply system (FTPSS), a certain short-circuit current is necessary for fault detection following a catenary fault. However, the static power converters (SPCs) have limited current overload capacity. To enable fault detection and rapid system recovery, SPCs must switch from voltage-frequency control (VFC) to fault current control (FCC). This mode switching process can cause issues such as transient voltage and synchronization problems during the soft start of SPCs, leading to abnormal mode transitions. To address these challenges, this paper proposes a communication-based collaboration and control strategy to suppress transient voltage and achieve synchronous soft start. Firstly, the paper identifies the transient voltage and synchronization issues under the continuous operation strategy of dual traction station FTPSS. Subsequently, a collaborative control strategy is introduced. Finally, simulation modeling is conducted on the PSCAD/EMTDC platform to validate the proposed strategy. The simulation results demonstrate that the strategy effectively suppresses transient voltage and achieves synchronous soft start, ensuring correct mode switching.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/auteee62881.2024.10869675
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Collaboration and Control Strategy for Dual Traction Station Flexible AC Traction Power System during Catenary Faults

J.F. Shao, Hua Shen, Xu Guo
Power Systems and Technologies
article

Collaboration and Control Strategy for Dual Traction Station Flexible AC Traction Power System during Catenary Faults

J.F. Shao, Hua Shen, Xu Guo
article en

Abstract

In the flexible AC traction power supply system (FTPSS), a certain short-circuit current is necessary for fault detection following a catenary fault. However, the static power converters (SPCs) have limited current overload capacity. To enable fault detection and rapid system recovery, SPCs must switch from voltage-frequency control (VFC) to fault current control (FCC). This mode switching process can cause issues such as transient voltage and synchronization problems during the soft start of SPCs, leading to abnormal mode transitions. To address these challenges, this paper proposes a communication-based collaboration and control strategy to suppress transient voltage and achieve synchronous soft start. Firstly, the paper identifies the transient voltage and synchronization issues under the continuous operation strategy of dual traction station FTPSS. Subsequently, a collaborative control strategy is introduced. Finally, simulation modeling is conducted on the PSCAD/EMTDC platform to validate the proposed strategy. The simulation results demonstrate that the strategy effectively suppresses transient voltage and achieves synchronous soft start, ensuring correct mode switching.

Northwestern Polytechnical University (CN), China Railway Corporation (CN), Tsinghua University (CN)
Affordable and clean energy
Openalex Percentile: Top 75%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Collaboration and Control Strategy for Dual Traction Station Flexible AC Traction Power System during Catenary Faults — J.F. Shao, Hua Shen, et al. · (2024) | TGRS Research Map | TGRS