Research on HVDC Transmission Protection Based on DC Line Boundary Elements

In this study, the smoothing reactor and DC filter of a DC transmission line are found to significantly attenuate the high-frequency components of the transient signal through simulation and analysis of internal and external faults of high-voltage direct current (HVDC) transmission lines. Consequently, the time-domain waveforms of the voltage fault component at the measurement end of transmission lines differ significantly among different fault types. When an external fault occurs, the high frequency component is low and the waveform is smooth, while when an internal fault occurs, the high frequency component is high and the waveform is steep. A multifractal spectrum is calculated based on the curvature characteristic value K<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">max</inf> of the multifractal spectrum that measures the irregularity of the voltage fault time-domain waveform. If the external fault occurs, Kmax is greater than 10, and if the internal fault occurs, Kmax is less than 10. Simulation tests with PSCAD demonstrate that this criterion is highly reliable, does not depend on fault location, and is resistant to transition resistance.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/auteee62881.2024.10869710
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on HVDC Transmission Protection Based on DC Line Boundary Elements

Wenchao Jia, Bojian Cao
High-Voltage Power Transmission Systems
article

Research on HVDC Transmission Protection Based on DC Line Boundary Elements

Wenchao Jia, Bojian Cao
article en

Abstract

In this study, the smoothing reactor and DC filter of a DC transmission line are found to significantly attenuate the high-frequency components of the transient signal through simulation and analysis of internal and external faults of high-voltage direct current (HVDC) transmission lines. Consequently, the time-domain waveforms of the voltage fault component at the measurement end of transmission lines differ significantly among different fault types. When an external fault occurs, the high frequency component is low and the waveform is smooth, while when an internal fault occurs, the high frequency component is high and the waveform is steep. A multifractal spectrum is calculated based on the curvature characteristic value K<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">max</inf> of the multifractal spectrum that measures the irregularity of the voltage fault time-domain waveform. If the external fault occurs, Kmax is greater than 10, and if the internal fault occurs, Kmax is less than 10. Simulation tests with PSCAD demonstrate that this criterion is highly reliable, does not depend on fault location, and is resistant to transition resistance.

North China Electric Power University (CN)
Openalex Percentile: Top 75%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on HVDC Transmission Protection Based on DC Line Boundary Elements — Wenchao Jia, Bojian Cao · (2024) | TGRS Research Map | TGRS