Study on Intermittent Discharge Characteristics of Typical Defects in GIS Under Different Vibration Conditions

The omission and false alarm of partial discharge insulation defect of gas insulated switchgear (GIS) seriously affect the safe and stable operation of GIS. Considering that GIS may be affected by various vibration factors in actual operation, this paper builds an intermittent discharge test platform for shock and vibration superimposed multi-source detection, and carries out experimental research on the characteristics of intermittent discharge under different vibration conditions for common internal typical insulation defects in GIS. The study found: The vibration state has a certain influence on the intermittent discharge of defects in GIS equipment, and the intermittent discharge law in the nonvibration state is consistent with that in the normal operation vibration. However, the insulation strength of metal particle defects decreases greatly under shock vibration, and with the continuous discharge process, the discharge interval develops from seconds to milliseconds, from intermittent discharge to continuous discharge. The research results are of great significance for broadening the understanding of intermittent discharge characteristics and promoting the field GIS discharge defect detection.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/auteee62881.2024.10869749
Primary Topic
Evaluation Methods in Various Fields
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Intermittent Discharge Characteristics of Typical Defects in GIS Under Different Vibration Conditions

Hao Zhan, Mengna Liu, Wen Zhou, Miao Jin et al.
Evaluation Methods in Various Fields
article

Study on Intermittent Discharge Characteristics of Typical Defects in GIS Under Different Vibration Conditions

Hao Zhan, Mengna Liu, Wen Zhou, Miao Jin, Tao Zhang, Hui Xu, Xu Yang, Jing Zhang
article en

Abstract

The omission and false alarm of partial discharge insulation defect of gas insulated switchgear (GIS) seriously affect the safe and stable operation of GIS. Considering that GIS may be affected by various vibration factors in actual operation, this paper builds an intermittent discharge test platform for shock and vibration superimposed multi-source detection, and carries out experimental research on the characteristics of intermittent discharge under different vibration conditions for common internal typical insulation defects in GIS. The study found: The vibration state has a certain influence on the intermittent discharge of defects in GIS equipment, and the intermittent discharge law in the nonvibration state is consistent with that in the normal operation vibration. However, the insulation strength of metal particle defects decreases greatly under shock vibration, and with the continuous discharge process, the discharge interval develops from seconds to milliseconds, from intermittent discharge to continuous discharge. The research results are of great significance for broadening the understanding of intermittent discharge characteristics and promoting the field GIS discharge defect detection.

NARI Group (China) (CN)
Openalex Percentile: Top 93%
Evaluation Methods in Various Fields
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on Intermittent Discharge Characteristics of Typical Defects in GIS Under Different Vibration Conditions — Hao Zhan, Mengna Liu, et al. · (2024) | TGRS Research Map | TGRS