A Fault Diagnosis Method for NPC Three-Level Inverters Based on VMD-SE and SMA-SVM

To tackle the challenges of low accuracy and high computational complexity in diagnosing open-circuit faults for NPC three-level inverters, this paper introduces a novel fault diagnosis approach that integrates Variational Mode Decomposition (VMD), Sample Entropy (SE), and an enhanced Slime Mold Algorithm (SMA) optimized Support Vector Machine (SVM). The method begins by decomposing the fault current signal using VMD and calculating the SE to identify fault characteristics. Next, it employs a correlation coefficient to filter out invalid Intrinsic Mode Functions (IMFs). Finally, an improved SMA is applied to optimize the SVM for accurate fault classification and identification. Simulation results show that this method outperforms traditional techniques in terms of effectiveness and accuracy.

Authors

Institutions

Publication Details

Published
2024-11-01
DOI
https://doi.org/10.1109/cac63892.2024.10864482
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fault Diagnosis Method for NPC Three-Level Inverters Based on VMD-SE and SMA-SVM

Baoye Song, Mengru Zhao, Qizheng Zhang
Smart Grid and Power Systems
article

A Fault Diagnosis Method for NPC Three-Level Inverters Based on VMD-SE and SMA-SVM

Baoye Song, Mengru Zhao, Qizheng Zhang
article en

Abstract

To tackle the challenges of low accuracy and high computational complexity in diagnosing open-circuit faults for NPC three-level inverters, this paper introduces a novel fault diagnosis approach that integrates Variational Mode Decomposition (VMD), Sample Entropy (SE), and an enhanced Slime Mold Algorithm (SMA) optimized Support Vector Machine (SVM). The method begins by decomposing the fault current signal using VMD and calculating the SE to identify fault characteristics. Next, it employs a correlation coefficient to filter out invalid Intrinsic Mode Functions (IMFs). Finally, an improved SMA is applied to optimize the SVM for accurate fault classification and identification. Simulation results show that this method outperforms traditional techniques in terms of effectiveness and accuracy.

Shandong University of Science and Technology (CN)
Openalex Percentile: Top 75%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.