Data-driven calibration of tri-axial magnetic sensors

Abstract This paper presents a data-driven calibration method for triaxial magnetic sensors that eliminates the need to solve sensor error model parameters. The calibration was achieved solely through the input and output of the sensor in a known magnetic field. Using both simulation and experimental data, this study employed a multilayer perceptron (MLP) algorithm as a data-driven calibration model. In static and dynamic calibration experiments conducted in a laboratory setting, the calibration performance of MLP was compared with that of traditional calibration algorithms. The experimental results demonstrate that in a static experiment under a 90 μT magnetic field, the sensor error after calibration using the data-driven method was reduced by 30.37% compared to the traditional method. In the dynamic experiments, the proposed method reduced the errors by 60.58% compared with the traditional method. The method proposed in this paper offers a new approach for improving the calibration accuracy and effective measurement range of triaxial magnetic sensors, and holds potential application value for other types of triaxial sensors.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2025-02-13
DOI
https://doi.org/10.1088/1361-6501/adb5a7
Citations
5
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
3.65
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Data-driven calibration of tri-axial magnetic sensors

qiusheng liu, Min Jin, Yiduo Guo, Yong Li et al.
5 citations
Measurement Science and Technology
Magnetic Field Sensors Techniques
3.65
article

Data-driven calibration of tri-axial magnetic sensors

qiusheng liu, Min Jin, Yiduo Guo, Yong Li, Fangfang Meng, Dongchen Tian
article en
5 citations

Abstract

Abstract This paper presents a data-driven calibration method for triaxial magnetic sensors that eliminates the need to solve sensor error model parameters. The calibration was achieved solely through the input and output of the sensor in a known magnetic field. Using both simulation and experimental data, this study employed a multilayer perceptron (MLP) algorithm as a data-driven calibration model. In static and dynamic calibration experiments conducted in a laboratory setting, the calibration performance of MLP was compared with that of traditional calibration algorithms. The experimental results demonstrate that in a static experiment under a 90 μT magnetic field, the sensor error after calibration using the data-driven method was reduced by 30.37% compared to the traditional method. In the dynamic experiments, the proposed method reduced the errors by 60.58% compared with the traditional method. The method proposed in this paper offers a new approach for improving the calibration accuracy and effective measurement range of triaxial magnetic sensors, and holds potential application value for other types of triaxial sensors.

Measurement Science and TechnologyVol. 36(3)
Beijing Institute of Technology (CN), Tsinghua–Berkeley Shenzhen Institute (CN)
Openalex Percentile: Top 8%
Magnetic Field Sensors Techniques
3.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.