Label-free full-thickness imaging of porcine vagus nerve fascicular anatomy by polarization-sensitive optical coherence tomography
<i>Objective.</i>Improving the efficacy of vagus nerve (VN) stimulation therapy requires a detailed understanding of the anatomical and functional organization of nerve fiber bundles and their fascicles. Various<i>ex-vivo</i>imaging platforms have been optimized for this purpose. However, all existing tools with micrometer resolution require labeling to enhance the fascicle contrast, and this labeling is resource-intensive and time-consuming. Polarization-sensitive optical coherence tomography (PS-OCT) was previously used to perform high-speed, label-free small animal (rat) sciatic nerve imaging but has not been applied for imaging the full-thickness large animal VNs (>1 mm diameter thick) due to tissue-limited imaging depth. We developed a PS-OCT platform that circumvents this problem and demonstrate high-speed label-free imaging of full-depth, multiple centimeters-long mammalian VNs for the first time.<i>Approach.</i>We employed a custom-built PS-OCT system with a dual-surface scanning microscope to capture opposite sides of the sample in a single frame. A tailored post-processing algorithm maximized fascicle contrast and merged the two surfaces together. Multi-centimeter-long porcine VNs were imaged.<i>Main Results.</i>Our approach reconstructed fascicle information throughout the full-thickness of the VN when compressed to a 650<i>μ</i>m thickness. Moreover, we cross-validated PS-OCT measurements of fascicular organization and retardance to assess myelination against pair histology from the same specimens, showing Spearman's rank correlation coefficient value of 0.69 (<i>p</i>-value < 0.001).<i>Significance.</i>We demonstrated a label-free optical imaging method for large-volume VN imaging. The time to image a 6.8 cm nerve was 680 s with 0.1 mm s<sup>-1</sup>longitudinal sample translation speed, which is more than two orders of magnitude faster than existing modalities that require labeling. With this gain in speed and the possibility of label-free quantification of a fascicle's myelination level, important studies on inter-sample variability in fascicle organization become feasible.
Authors
- Fernando Pozzi Semeghini Guastaldi (ORCID: https://orcid.org/0000-0001-8554-8849)
- Rex Chin-Hao Chen (ORCID: https://orcid.org/0000-0003-3616-3576)
- Megan L. Settell (ORCID: https://orcid.org/0000-0002-2924-360X)
- Yong-Chul Yoon (ORCID: https://orcid.org/0000-0002-0618-7510)
- Kip A. Ludwig (ORCID: https://orcid.org/0000-0003-4889-1941)
- Ilyas Saytashev
- Benjamin J. Vakoc (ORCID: https://orcid.org/0000-0002-6623-3515)
- Daniel X. Hammer (ORCID: https://orcid.org/0000-0003-0532-1914)
Institutions
- United States Food and Drug Administration (US)
- Center for Devices and Radiological Health (US)
- University of Wisconsin–Madison (US)
- Harvard University (US)
- Massachusetts General Hospital (US)
- Center for Systems Biology (US)
- Massachusetts Institute of Technology (US)
Publication Details
- Journal
- Journal of Neural Engineering
- Published
- 2025-02-13
- DOI
- https://doi.org/10.1088/1741-2552/adb5c3
- Citations
- 1
- Primary Topic
- Optical Coherence Tomography Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.67