Ultra-low fluence irradiation with energetic heavy ion pulsed beam using a modified electrostatic raster scanner

Abstract A method for performing low fluence pulsed irradiations with energetic heavy ions is presented. A raster scanner, placed upstream from a sample target chamber, is externally driven by a voltage pulse generated by a function generator. The configuration is similar to an electrostatic chopper, where a voltage difference across the scanner’s electrodes sweeps the beam across the sample, placed slightly off center from the beam axis, resulting in a short irradiation pulse on the sample and a low particle fluence. Such a system was developed at the Centre for Micro Analysis of Materials (CMAM) facility and characterized using 9 MeV F and 18 MeV Cl ions. The system can generate pulses of a few microseconds duration, depending on ion energy and charge state. A diagnostic method for measuring the fluence on the samples by counting etched ion tracks is described. A fluence on the order of 10 6 cm −2 was obtained by this method. This method could be adopted by other tandem ion accelerator facilities through simple and inexpensive modifications of existing beam handling instruments.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2025-02-13
DOI
https://doi.org/10.1088/1402-4896/adb5d4
Primary Topic
Ion-surface interactions and analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-low fluence irradiation with energetic heavy ion pulsed beam using a modified electrostatic raster scanner

Santanu Kumar Padhi, Y. Zamora Garcia, Joseph Graham, J. Olivares et al.
Physica Scripta
Ion-surface interactions and analysis
article

Ultra-low fluence irradiation with energetic heavy ion pulsed beam using a modified electrostatic raster scanner

Santanu Kumar Padhi, Y. Zamora Garcia, Joseph Graham, J. Olivares, E. Enríquez, Miguel L. Crespillo, Vicente García Távora
article en

Abstract

Abstract A method for performing low fluence pulsed irradiations with energetic heavy ions is presented. A raster scanner, placed upstream from a sample target chamber, is externally driven by a voltage pulse generated by a function generator. The configuration is similar to an electrostatic chopper, where a voltage difference across the scanner’s electrodes sweeps the beam across the sample, placed slightly off center from the beam axis, resulting in a short irradiation pulse on the sample and a low particle fluence. Such a system was developed at the Centre for Micro Analysis of Materials (CMAM) facility and characterized using 9 MeV F and 18 MeV Cl ions. The system can generate pulses of a few microseconds duration, depending on ion energy and charge state. A diagnostic method for measuring the fluence on the samples by counting etched ion tracks is described. A fluence on the order of 10 6 cm −2 was obtained by this method. This method could be adopted by other tandem ion accelerator facilities through simple and inexpensive modifications of existing beam handling instruments.

Physica ScriptaVol. 100(3)
Consejo Superior de Investigaciones Científicas (ES), Missouri University of Science and Technology (US), Unidades Centrales Científico-Técnicas (ES), Universidad Autónoma de Madrid (ES), University of Tennessee at Knoxville (US)
Affordable and clean energy
Openalex Percentile: Top 97%
Ion-surface interactions and analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.