A Non-Calibration Nonlinear Errors Correction Method for Phase-Shifting Patterns

To reduce phase errors caused by nonlinear responses in the measurement system, we propose a non-calibration correction method for nonlinear errors in phase-shifting patterns. First, the captured grating fringes are transformed using a Fourier transform to convert the images from the gray scale to the frequency domain. The first harmonic frequency is then determined using an appropriate method. Second, the appropriate filter cutoff frequency is calculated by combining the phase-shift algorithm's sensitivity to different harmonics with frequency response curves. Low-pass filtering is then performed on the phase-shift patterns to suppress high frequencies caused by nonlinear responses, thus reducing phase errors in the actual measurement process. Finally, the standard plane and other irregularly shaped objects were reconstructed using the proposed method and other techniques. Measurement errors under different conditions were then compared. Experimental results show that the proposed method significantly suppresses gamma nonlinear responses and achieves high measurement accuracy and efficiency.

Authors

Institutions

Publication Details

Published
2024-11-01
DOI
https://doi.org/10.1109/cac63892.2024.10865249
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Non-Calibration Nonlinear Errors Correction Method for Phase-Shifting Patterns

Yujie Zheng, Shiqian Wu, Bin Chen
Sensor Technology and Measurement Systems
article

A Non-Calibration Nonlinear Errors Correction Method for Phase-Shifting Patterns

Yujie Zheng, Shiqian Wu, Bin Chen
article en

Abstract

To reduce phase errors caused by nonlinear responses in the measurement system, we propose a non-calibration correction method for nonlinear errors in phase-shifting patterns. First, the captured grating fringes are transformed using a Fourier transform to convert the images from the gray scale to the frequency domain. The first harmonic frequency is then determined using an appropriate method. Second, the appropriate filter cutoff frequency is calculated by combining the phase-shift algorithm's sensitivity to different harmonics with frequency response curves. Low-pass filtering is then performed on the phase-shift patterns to suppress high frequencies caused by nonlinear responses, thus reducing phase errors in the actual measurement process. Finally, the standard plane and other irregularly shaped objects were reconstructed using the proposed method and other techniques. Measurement errors under different conditions were then compared. Experimental results show that the proposed method significantly suppresses gamma nonlinear responses and achieves high measurement accuracy and efficiency.

Wuhan University of Science and Technology (CN)
Openalex Percentile: Top 68%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.