Heat exchanger design and performance evaluation for a high-temperature heat pump system under different two-phase correlations: 4E analysis

Supplying district heat and assisting the integration of renewable electricity, high-temperature heat pump technology is foreseen to play an essential role in renewable energy-powered thermal energy storage systems. However, existing studies on high-temperature heat pump performance prediction are usually based on utilizing specific heat transfer correlations of heat exchangers. It is difficult to guide the selection and combination of the two-phase correlations in the heat exchanger design and system performance assessment of the high-temperature heat pump. In the present study, we aim to focus on the impact of different two-phase correlations, and a comparative study is conducted among 8 correlations (4 flow condensation ones and 4 flow boiling ones) adopted for component design and system performance prediction. The results show that for designed condensers or evaporators, the dimensions, costs, and carbon emissions are significantly affected by different two-phase correlations. Among 16 pairs of two-phase correlations, little fluctuation of the system performance is observed at the design heat source temperature 80 °C. While at off-design heat source temperatures of 85, 90 or 95 °C, the energetic and exergetic performance parameters are significantly affected with high relative differences (9.88% of heating capacity, 3.27% of coefficient of performance, and 6.76% of exergy efficiency). Also, the system's economic and environmental performance indexes are influenced to some extent, with visible relative uncertainties (1.91% of the heating cost, 4.44% of the payback time, and 6.38% of the carbon emission). This research will help to promote the selection and utilization of two-phase correlations for the plate heat exchanger design and system assessment in larger renewable energy-powered high-temperature heat pump applications.

Authors

Publication Details

Journal
Applied Energy
Published
2025-02-13
DOI
https://doi.org/10.1016/j.apenergy.2025.125492
Citations
11
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
7.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat exchanger design and performance evaluation for a high-temperature heat pump system under different two-phase correlations: 4E analysis

Xiong Wu, Yan Yang, Chuang Wen, Ji Zhang et al.
11 citations
Applied Energy
Heat Transfer and Optimization
7.85
article

Heat exchanger design and performance evaluation for a high-temperature heat pump system under different two-phase correlations: 4E analysis

Xiong Wu, Yan Yang, Chuang Wen, Ji Zhang, Xiaohui Huang, Bo Ma, Ding Wu
article en
11 citations

Abstract

Supplying district heat and assisting the integration of renewable electricity, high-temperature heat pump technology is foreseen to play an essential role in renewable energy-powered thermal energy storage systems. However, existing studies on high-temperature heat pump performance prediction are usually based on utilizing specific heat transfer correlations of heat exchangers. It is difficult to guide the selection and combination of the two-phase correlations in the heat exchanger design and system performance assessment of the high-temperature heat pump. In the present study, we aim to focus on the impact of different two-phase correlations, and a comparative study is conducted among 8 correlations (4 flow condensation ones and 4 flow boiling ones) adopted for component design and system performance prediction. The results show that for designed condensers or evaporators, the dimensions, costs, and carbon emissions are significantly affected by different two-phase correlations. Among 16 pairs of two-phase correlations, little fluctuation of the system performance is observed at the design heat source temperature 80 °C. While at off-design heat source temperatures of 85, 90 or 95 °C, the energetic and exergetic performance parameters are significantly affected with high relative differences (9.88% of heating capacity, 3.27% of coefficient of performance, and 6.76% of exergy efficiency). Also, the system's economic and environmental performance indexes are influenced to some extent, with visible relative uncertainties (1.91% of the heating cost, 4.44% of the payback time, and 6.38% of the carbon emission). This research will help to promote the selection and utilization of two-phase correlations for the plate heat exchanger design and system assessment in larger renewable energy-powered high-temperature heat pump applications.

Applied EnergyVol. 384
National Natural Science Foundation of China, State Key Laboratory of Disaster Prevention and Reduction for Power Grid Transmission and Distribution Equipment, Engineering and Physical Sciences Research Council
Affordable and clean energy
Openalex Percentile: Top 2%
Heat Transfer and Optimization
7.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.