A High-Sensitivity Frequency Shift Detector for QCM-Based Miniaturized Sensing System

As a micro-gravimetric sensor, QCM is widely used in gas, particle, and virus detection. However, due to its high resonant frequency, the detection response (frequency shift) of QCM often requires expensive and bulky high-frequency analysis equipment such as vector network analyzer. In order to realize the simplicity and convenience of QCM analysis, so as to realize the ability of in-situ and real-time detection based on QCM, a miniaturized frequency shift detector based on a PLL circuit is developed., with a size of 40 mm×40mm. The proposed detector achieves a high frequency shift detection sensitivity of 1.859 mV/Hz by calibration. The developed detection system demonstrated an ability to detect two kinds of heavy metal ions, which also represents the potential applications for outdoors detection.

Authors

Institutions

Publication Details

Published
2024-11-01
DOI
https://doi.org/10.1109/cac63892.2024.10865741
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High-Sensitivity Frequency Shift Detector for QCM-Based Miniaturized Sensing System

Haozhen Chi, Dibo Hou, Yunqi Cao, Shuyu Fan et al.
Sensor Technology and Measurement Systems
article

A High-Sensitivity Frequency Shift Detector for QCM-Based Miniaturized Sensing System

Haozhen Chi, Dibo Hou, Yunqi Cao, Shuyu Fan, Chenyang Gao, Yipei Yao
article en

Abstract

As a micro-gravimetric sensor, QCM is widely used in gas, particle, and virus detection. However, due to its high resonant frequency, the detection response (frequency shift) of QCM often requires expensive and bulky high-frequency analysis equipment such as vector network analyzer. In order to realize the simplicity and convenience of QCM analysis, so as to realize the ability of in-situ and real-time detection based on QCM, a miniaturized frequency shift detector based on a PLL circuit is developed., with a size of 40 mm×40mm. The proposed detector achieves a high frequency shift detection sensitivity of 1.859 mV/Hz by calibration. The developed detection system demonstrated an ability to detect two kinds of heavy metal ions, which also represents the potential applications for outdoors detection.

Zhejiang University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 68%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.