Method for Correcting the Muscle Fiber Orientation Determined by a T-Shaped Transducer in Ultrasound Shear Wave Elastography

Shear wave elastography (SWE) is a quantitative imaging method that could be used for clinical assessment of musculoskeletal stiffness, particularly in disease diagnosis and rehabilitation evaluation. However, the elastic anisotropy of skeletal muscle leads to uncertainties in shear wave velocity (SWV) measurements in SWE because the SWV varies with muscle fiber orientation. Therefore, many studies have conducted 360° rotational measurements of SWV to determine the elastic anisotropy of muscle; however, the extended data acquisition time of this approach limits its clinical utility. In this study, a T-shaped transducer was used for rapidly measuring the longitudinal and transverse SWVs ( $\textit {SWV}_{L}$ and $\textit {SWV}_{T}$ ) of muscle through an ellipse fitting method to estimate the fiber orientation angle when the excitation is normal to the material axis. The performance of this approach was examined by conducting a homogeneous elastic phantom experiment, which indicated that the proposed T-shaped transducer generated shear waves in three directions by applying a supersonic push at the junction of the transducer. The error between the measured SWVs and ground truth was approximately 6.5%. The proposed T-shaped transducer was also used to measure the SWV in the biceps brachii of four healthy individuals. The $\textit {SWV}_{L}$ and $\textit {SWV}_{T}$ values measured with this transducer were 2.47 and 1.09 m/s, respectively, which were consistent with the SWVs obtained under 360° rotation and in the literature (an error of ~4%). All experimental results were consistent with the results obtained under 360° rotation, which indicates that the proposed method enables the rapid and stable estimation of muscle fiber orientation in SWE.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Imaging
Published
2025-02-13
DOI
https://doi.org/10.1109/tmi.2025.3541321
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method for Correcting the Muscle Fiber Orientation Determined by a T-Shaped Transducer in Ultrasound Shear Wave Elastography

Chien‐Chung Huang, Wei-Rei Su, Guo‐Xuan Xu, Chien Chen
IEEE Transactions on Medical Imaging
Ultrasound Imaging and Elastography
article

Method for Correcting the Muscle Fiber Orientation Determined by a T-Shaped Transducer in Ultrasound Shear Wave Elastography

Chien‐Chung Huang, Wei-Rei Su, Guo‐Xuan Xu, Chien Chen
article en

Abstract

Shear wave elastography (SWE) is a quantitative imaging method that could be used for clinical assessment of musculoskeletal stiffness, particularly in disease diagnosis and rehabilitation evaluation. However, the elastic anisotropy of skeletal muscle leads to uncertainties in shear wave velocity (SWV) measurements in SWE because the SWV varies with muscle fiber orientation. Therefore, many studies have conducted 360° rotational measurements of SWV to determine the elastic anisotropy of muscle; however, the extended data acquisition time of this approach limits its clinical utility. In this study, a T-shaped transducer was used for rapidly measuring the longitudinal and transverse SWVs ( $\textit {SWV}_{L}$ and $\textit {SWV}_{T}$ ) of muscle through an ellipse fitting method to estimate the fiber orientation angle when the excitation is normal to the material axis. The performance of this approach was examined by conducting a homogeneous elastic phantom experiment, which indicated that the proposed T-shaped transducer generated shear waves in three directions by applying a supersonic push at the junction of the transducer. The error between the measured SWVs and ground truth was approximately 6.5%. The proposed T-shaped transducer was also used to measure the SWV in the biceps brachii of four healthy individuals. The $\textit {SWV}_{L}$ and $\textit {SWV}_{T}$ values measured with this transducer were 2.47 and 1.09 m/s, respectively, which were consistent with the SWVs obtained under 360° rotation and in the literature (an error of ~4%). All experimental results were consistent with the results obtained under 360° rotation, which indicates that the proposed method enables the rapid and stable estimation of muscle fiber orientation in SWE.

IEEE Transactions on Medical ImagingVol. 44(6)
National Cheng Kung University Hospital (TW), National Cheng Kung University (TW)
National Health Research Institutes
Openalex Percentile: Top 96%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.