Measurements of Breakdown Voltage Characteristics of Medium Voltage Vacuum Circuit Breaker After Current Interruption

We present a test circuit for measuring the breakdown voltage characteristics of a vacuum circuit breaker after current interruption process. The test circuit combines the high current part from the synthetic test circuit as per IEC Std. 62271-101 with the so-called Rabus high voltage part. The high current part reproduces the current phase before voltage build-up occurring after zero current crossing, then the Rabus high voltage part provides voltage breakdowns constituting breakdown voltage characteristics. The high current part can be adjusted to represent the actual current conditions which influences the physical conditions of the contact system upon which the interruption process is highly dependent. To illustrate the measuring system and the measuring procedure, the measurements of the breakdown voltages are reported for a commercial 12 kV/1250 A/31.5 kA vacuum circuit breaker. The breakdown voltages are measured primarily as a function of time and then converted via a contact travel curve into the vacuum interrupter contact gap function. This allows the results to be converted back and applied to a breaker with the same characteristics of the vacuum interrupter unit operating in similar current conditions, but with different mechanical characteristics of the breaker-specific actuator than the one used in testing.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2025-02-13
DOI
https://doi.org/10.1109/tpwrd.2025.3541301
Citations
1
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
1.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurements of Breakdown Voltage Characteristics of Medium Voltage Vacuum Circuit Breaker After Current Interruption

Waldemar Chmielak, Radosław Szreder, Zbigniew Pochanke, Marcin Szewczyk et al.
1 citations
IEEE Transactions on Power Delivery
Vacuum and Plasma Arcs
1.25
article

Measurements of Breakdown Voltage Characteristics of Medium Voltage Vacuum Circuit Breaker After Current Interruption

Waldemar Chmielak, Radosław Szreder, Zbigniew Pochanke, Marcin Szewczyk, Szymon Stoczko
article en
1 citations

Abstract

We present a test circuit for measuring the breakdown voltage characteristics of a vacuum circuit breaker after current interruption process. The test circuit combines the high current part from the synthetic test circuit as per IEC Std. 62271-101 with the so-called Rabus high voltage part. The high current part reproduces the current phase before voltage build-up occurring after zero current crossing, then the Rabus high voltage part provides voltage breakdowns constituting breakdown voltage characteristics. The high current part can be adjusted to represent the actual current conditions which influences the physical conditions of the contact system upon which the interruption process is highly dependent. To illustrate the measuring system and the measuring procedure, the measurements of the breakdown voltages are reported for a commercial 12 kV/1250 A/31.5 kA vacuum circuit breaker. The breakdown voltages are measured primarily as a function of time and then converted via a contact travel curve into the vacuum interrupter contact gap function. This allows the results to be converted back and applied to a breaker with the same characteristics of the vacuum interrupter unit operating in similar current conditions, but with different mechanical characteristics of the breaker-specific actuator than the one used in testing.

IEEE Transactions on Power DeliveryVol. 40(2)
Warsaw University of Technology (PL), Polska Grupa Energetyczna (Poland) (PL)
Affordable and clean energy
Openalex Percentile: Top 24%
Vacuum and Plasma Arcs
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measurements of Breakdown Voltage Characteristics of Medium Voltage Vacuum Circuit Breaker After Current Interruption — Waldemar Chmielak, Radosław Szreder, et al. · IEEE Transactions on Power Delivery (2025) | TGRS Research Map | TGRS