Earth Fault Detection Method for TN-C Systems Based on Comparison of Current Deviations

The existing low voltage (LV) earth fault detection techniques using residual current measurements cannot be effectively applied to the multi-earthed TN-C system. When an earth fault occurs on the multi-earthed TN-C system, the fault current passes through the combined protective and neutral (PEN) conductor back to the source, resulting in a low residual current. However, unbalanced load switching also generates residual current through the same path back to the source, thus making fault discrimination very difficult. To address this problem, the four-wire multi-earthed TN-C system was analyzed by decoupling the mode 0 and the mode N of the equivalent circuit so that the current characteristics can be clearly studied. A new earth fault detection method is developed which compares the residual current deviation with the PEN conductor current deviation. The scheme uses amplitude ratio and phase angle difference between these two measurements to discriminate between earth faults and unbalanced load switching. The feasibility of the proposed method was verified by digital simulation and by physical tests in an actual LV distribution network. Compared to approaches based only on residual current, the proposed method demonstrates better sensitivity and reliability.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2025-02-13
DOI
https://doi.org/10.1109/tpwrd.2025.3541201
Citations
1
Primary Topic
Fault Detection and Control Systems
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Earth Fault Detection Method for TN-C Systems Based on Comparison of Current Deviations

Tony Yip, Z. T. Sun, Wei Wang, Bingyin Xu
1 citations
IEEE Transactions on Power Delivery
Fault Detection and Control Systems
1.21
article

Earth Fault Detection Method for TN-C Systems Based on Comparison of Current Deviations

Tony Yip, Z. T. Sun, Wei Wang, Bingyin Xu
article en
1 citations

Abstract

The existing low voltage (LV) earth fault detection techniques using residual current measurements cannot be effectively applied to the multi-earthed TN-C system. When an earth fault occurs on the multi-earthed TN-C system, the fault current passes through the combined protective and neutral (PEN) conductor back to the source, resulting in a low residual current. However, unbalanced load switching also generates residual current through the same path back to the source, thus making fault discrimination very difficult. To address this problem, the four-wire multi-earthed TN-C system was analyzed by decoupling the mode 0 and the mode N of the equivalent circuit so that the current characteristics can be clearly studied. A new earth fault detection method is developed which compares the residual current deviation with the PEN conductor current deviation. The scheme uses amplitude ratio and phase angle difference between these two measurements to discriminate between earth faults and unbalanced load switching. The feasibility of the proposed method was verified by digital simulation and by physical tests in an actual LV distribution network. Compared to approaches based only on residual current, the proposed method demonstrates better sensitivity and reliability.

IEEE Transactions on Power DeliveryVol. 40(2)
Shandong University of Technology (CN), Shandong University (CN), KES International (GB)
Climate action
Openalex Percentile: Top 25%
Fault Detection and Control Systems
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.