Enhancing Insulator String Performance: Pollution and Icing Flashover Analysis Through Artificial Neural Network-Based Layout Optimization for Inverted T-Type String

This study explores the impact of various high-voltage insulator string configurations on pollution and icing flashover characteristics under different environmental conditions. The inverted T-string design is suggested, offering improvements over the traditional I-string configuration. An experimental investigation is conducted using high-voltage glass-type disks (LD-160), along with the development of two artificial neural network (ANN) models to simulate and predict flashover voltages. The results demonstrate that the inverted T-string arrangement enhances the flashover voltage for polluted insulator strings by approximately 7% and increases the icing flashover voltage by 3.43%–5.01% compared to standard I-strings. The ANN models successfully determine optimal insulator configurations, demonstrating their potential to enhance high-voltage insulation performance with minimal experimentation. This study emphasizes the innovative use of ANN in optimizing insulator string arrangements, providing a practical solution for tackling pollution and icing issues in power systems.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Dielectrics and Electrical Insulation
Published
2025-02-13
DOI
https://doi.org/10.1109/tdei.2025.3542009
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Insulator String Performance: Pollution and Icing Flashover Analysis Through Artificial Neural Network-Based Layout Optimization for Inverted T-Type String

Salah Kamel, Asad Ullah Awan, Xingliang Jiang, Mahmoud A. Ali
IEEE Transactions on Dielectrics and Electrical Insulation
High voltage insulation and dielectric phenomena
article

Enhancing Insulator String Performance: Pollution and Icing Flashover Analysis Through Artificial Neural Network-Based Layout Optimization for Inverted T-Type String

Salah Kamel, Asad Ullah Awan, Xingliang Jiang, Mahmoud A. Ali
article en

Abstract

This study explores the impact of various high-voltage insulator string configurations on pollution and icing flashover characteristics under different environmental conditions. The inverted T-string design is suggested, offering improvements over the traditional I-string configuration. An experimental investigation is conducted using high-voltage glass-type disks (LD-160), along with the development of two artificial neural network (ANN) models to simulate and predict flashover voltages. The results demonstrate that the inverted T-string arrangement enhances the flashover voltage for polluted insulator strings by approximately 7% and increases the icing flashover voltage by 3.43%–5.01% compared to standard I-strings. The ANN models successfully determine optimal insulator configurations, demonstrating their potential to enhance high-voltage insulation performance with minimal experimentation. This study emphasizes the innovative use of ANN in optimizing insulator string arrangements, providing a practical solution for tackling pollution and icing issues in power systems.

IEEE Transactions on Dielectrics and Electrical InsulationVol. 32(3)
King Fahd University of Petroleum and Minerals (SA), Chongqing University (CN), Al-Azhar University (EG), Aswan University (EG)
Climate action
Openalex Percentile: Top 98%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.