N-Deficient B-Doped <i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS Heterojunction-Based PEC-FL Biosensor Assisted by CRISPR-Cas12a System for Ultrasensitive Determination of microRNA

Near-infrared light (NIR)-driven photoelectrochemical (PEC) processes are mainly faced with the limitation of weak photocurrents. Here, N-deficient B-doped <i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS (NB-<i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS) is proposed to construct a NIR-driven PEC biosensor assisted by CRISPR-Cas12a system for the determination of microRNA-21 (miRNA-21). To promote the optical absorption as well as the separation of photogenerated electrons and holes of <i>g</i>-C<sub>3</sub>N<sub>4</sub>, NB-<i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS is constructed via engineering the electronic and band structure in terms of N defect, B doping, and heterojunction, achieving high PEC performance. To obtain the high luminescence efficiency for exciting NB-<i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS under NIR, the core-shell NaYF<sub>4</sub>:Yb<sup>3+</sup>, Tm<sup>3+</sup>@NaYF<sub>4</sub> upconversion nanoparticles (UCNPs) with repaired defects are prepared. Furthermore, the rolling circle amplification (RCA)-assisted CRISPR-Cas12a system is integrated to fragment the DNA on UCNPs, achieving sensitive detection of miRNA-21. On the one hand, the uncleavaged signal probes on UCNPs combined with NB-<i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS through π-π stacking interaction, generating photocurrents under the irradiation of NIR. On the other hand, the cleavaged signal probes which cannot link with NB-<i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS exhibited the fluorescence (FL) signals. The proposed PEC-FL dual-mode biosensor provides a mutual authentication of testing results and demonstrates ultrasensitivity (the detection limit of 1.1 fM for PEC mode and 7.0 fM for FL mode) and excellent specificity, which is promising in the clinical analysis of miRNA.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-02-13
DOI
https://doi.org/10.1021/acs.analchem.4c05841
Citations
35
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
28.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

N-Deficient B-Doped g-C3N4/CdS Heterojunction-Based PEC-FL Biosensor Assisted by CRISPR-Cas12a System for Ultrasensitive Determination of microRNA

Xuemin Zhou, Huijie Wang, Pengfei Shi, Shuzhen Lv et al.
35 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
28.21
article

N-Deficient B-Doped g-C3N4/CdS Heterojunction-Based PEC-FL Biosensor Assisted by CRISPR-Cas12a System for Ultrasensitive Determination of microRNA

Xuemin Zhou, Huijie Wang, Pengfei Shi, Shuzhen Lv, Sai Bi, Yingna Bi, Haoyu Zhang, Qingyu Du
article en
35 citations

Abstract

Near-infrared light (NIR)-driven photoelectrochemical (PEC) processes are mainly faced with the limitation of weak photocurrents. Here, N-deficient B-doped <i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS (NB-<i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS) is proposed to construct a NIR-driven PEC biosensor assisted by CRISPR-Cas12a system for the determination of microRNA-21 (miRNA-21). To promote the optical absorption as well as the separation of photogenerated electrons and holes of <i>g</i>-C<sub>3</sub>N<sub>4</sub>, NB-<i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS is constructed via engineering the electronic and band structure in terms of N defect, B doping, and heterojunction, achieving high PEC performance. To obtain the high luminescence efficiency for exciting NB-<i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS under NIR, the core-shell NaYF<sub>4</sub>:Yb<sup>3+</sup>, Tm<sup>3+</sup>@NaYF<sub>4</sub> upconversion nanoparticles (UCNPs) with repaired defects are prepared. Furthermore, the rolling circle amplification (RCA)-assisted CRISPR-Cas12a system is integrated to fragment the DNA on UCNPs, achieving sensitive detection of miRNA-21. On the one hand, the uncleavaged signal probes on UCNPs combined with NB-<i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS through π-π stacking interaction, generating photocurrents under the irradiation of NIR. On the other hand, the cleavaged signal probes which cannot link with NB-<i>g</i>-C<sub>3</sub>N<sub>4</sub>/CdS exhibited the fluorescence (FL) signals. The proposed PEC-FL dual-mode biosensor provides a mutual authentication of testing results and demonstrates ultrasensitivity (the detection limit of 1.1 fM for PEC mode and 7.0 fM for FL mode) and excellent specificity, which is promising in the clinical analysis of miRNA.

Analytical ChemistryVol. 97(7)
Qingdao University (CN), Linyi University (CN)
Qingdao Postdoctoral Science Foundation, National Natural Science Foundation of China, Natural Science Foundation of Shandong Province, Taishan Scholar Foundation of Shandong Province, Qingdao University, National Key Research and Development Program of China
Openalex Percentile: Top 0%
Advanced biosensing and bioanalysis techniques
28.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.