Experiment-modeling studies comparing energy dissipation in the DIII-D SAS and SAS-VW divertors

• A set of novel Small Angle Slot divertors (SAS and SAS-VW) were tested on DIII-D. • These divertors use neutral buildup and ExB drifts to increase power dissipation. • The separatrix density n e,sep is the key controlling parameter for dissipation. • Dissipation performance for both divertors is in contrast to modeling predictions. • In-slot puffing detaches at lower upstream densities, better core-edge integration. • Modeling disagreement needs resolution for confidence in future machine designs. Recent DIII-D experiments on Small Angle Slot (SAS) divertors have confirmed that a combination of divertor closure and target shaping can enhance cooling across the divertor target and increase energy dissipation, but with significant dependence on B T (toroidal magnetic field) direction. In these novel divertors, the roles of closure, target shaping, drifts, and scale lengths are all interconnected in optimizing dissipation, with the separatrix electron density n eSEP being the key parameter associated with the level of dissipation/detachment. After modifying the original flat-targeted graphite SAS to include a V shape with a tungsten coating on the outer side of the divertor (SAS-VW), matched series of discharges were run to compare to detailed SOLPS-ITER modeling. Experimentally, when run as designed with the outer strike point at the slot vertex, SAS-VW requires nearly identical n eSEP for detachment as the original SAS, with little difference in dissipation for the new geometry. This is in contrast to (1) earlier modeling predictions that a small change of the SAS geometry to a V shape should enhance dissipation at the same n eSEP for magnetic configurations having better H-mode access (ion B × ∇B drift directed into the divertor), and (2) despite the achievement of significantly higher (2-7x) neutral pressures and compression in the SAS-VW slot. Comparisons of experimental density scans to the most recent SOLPS-ITER modeling with ExB drifts show reasonable agreement for dissipation/detachment onset when using separatrix density as the independent parameter. In order to help understand the discrepancy in modeled vs actual performance for the new configuration, additional measurements varying gas injection location and impurity injection were undertaken. In-slot D 2 gas fueling is more effective (5–22 %) in promoting detachment, in accord with modeling. In-slot impurity injection (N 2 or Ne) can yield 30 % lower core Z eff and 15 % less confinement degradation after detachment compared to main chamber puffing, as well as relatively lower tungsten leakage from the divertor. Modeling can also reproduce the improved detachment seen as the strike point moves inboard of the slot vertex. While we can explain the effects of the most important parameters causing energy dissipation in these slot divertors, it remains that many aspects of their behavior cannot be accurately modeled using state-of-art codes such as SOLPS-ITER. This is of concern for future model-driven designs utilizing similar V-shaped geometries.

Authors

Institutions

Publication Details

Journal
Nuclear Materials and Energy
Published
2025-02-13
DOI
https://doi.org/10.1016/j.nme.2025.101903
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experiment-modeling studies comparing energy dissipation in the DIII-D SAS and SAS-VW divertors

X. Ma, A.G. McLean, J.G. Watkins, T. Abrams et al.
Nuclear Materials and Energy
Magnetic confinement fusion research
article

Experiment-modeling studies comparing energy dissipation in the DIII-D SAS and SAS-VW divertors

X. Ma, A.G. McLean, J.G. Watkins, T. Abrams, A.W. Leonard, R. Maurizio, M.W. Shafer, Huiqian Wang, C. Murphy, F. Effenberg, David Donovan, Dinh Truong, J.H. Yu, J. L. Herfindal, Jun Ren, D. M. Thomas, Rui Ding, A.W. Hyatt
article en

Abstract

• A set of novel Small Angle Slot divertors (SAS and SAS-VW) were tested on DIII-D. • These divertors use neutral buildup and ExB drifts to increase power dissipation. • The separatrix density n e,sep is the key controlling parameter for dissipation. • Dissipation performance for both divertors is in contrast to modeling predictions. • In-slot puffing detaches at lower upstream densities, better core-edge integration. • Modeling disagreement needs resolution for confidence in future machine designs. Recent DIII-D experiments on Small Angle Slot (SAS) divertors have confirmed that a combination of divertor closure and target shaping can enhance cooling across the divertor target and increase energy dissipation, but with significant dependence on B T (toroidal magnetic field) direction. In these novel divertors, the roles of closure, target shaping, drifts, and scale lengths are all interconnected in optimizing dissipation, with the separatrix electron density n eSEP being the key parameter associated with the level of dissipation/detachment. After modifying the original flat-targeted graphite SAS to include a V shape with a tungsten coating on the outer side of the divertor (SAS-VW), matched series of discharges were run to compare to detailed SOLPS-ITER modeling. Experimentally, when run as designed with the outer strike point at the slot vertex, SAS-VW requires nearly identical n eSEP for detachment as the original SAS, with little difference in dissipation for the new geometry. This is in contrast to (1) earlier modeling predictions that a small change of the SAS geometry to a V shape should enhance dissipation at the same n eSEP for magnetic configurations having better H-mode access (ion B × ∇B drift directed into the divertor), and (2) despite the achievement of significantly higher (2-7x) neutral pressures and compression in the SAS-VW slot. Comparisons of experimental density scans to the most recent SOLPS-ITER modeling with ExB drifts show reasonable agreement for dissipation/detachment onset when using separatrix density as the independent parameter. In order to help understand the discrepancy in modeled vs actual performance for the new configuration, additional measurements varying gas injection location and impurity injection were undertaken. In-slot D 2 gas fueling is more effective (5–22 %) in promoting detachment, in accord with modeling. In-slot impurity injection (N 2 or Ne) can yield 30 % lower core Z eff and 15 % less confinement degradation after detachment compared to main chamber puffing, as well as relatively lower tungsten leakage from the divertor. Modeling can also reproduce the improved detachment seen as the strike point moves inboard of the slot vertex. While we can explain the effects of the most important parameters causing energy dissipation in these slot divertors, it remains that many aspects of their behavior cannot be accurately modeled using state-of-art codes such as SOLPS-ITER. This is of concern for future model-driven designs utilizing similar V-shaped geometries.

Nuclear Materials and EnergyVol. 42
Lawrence Livermore National Laboratory (US), Oak Ridge National Laboratory (US), Princeton Plasma Physics Laboratory (US), Institute of Plasma Physics (CN), General Atomics (United States) (US), University of Tennessee at Knoxville (US)
Affordable and clean energy
Openalex Percentile: Top 98%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.