Phase Angle Measurement System for Energy Meter Composed of Multiple Single-Phase Measuring Chips

Traditional three-phase electric energy meters adopt the current transformer sampling method, which is susceptible to constant magnetic field interference and easy DC saturation, while the manganese-copper sampling method can well solve the problem of anti-DC component of the electric energy meter. When disturbed by a magnetic field, the energy error jumps, Therefore the all-manganese-copper sampling scheme used on the three-phase electric energy meter mainly faces the problems of electrical isolation of the three-phase metering circuit and the problem of asynchronous sampling of the three-phase signal. This paper introduces a phase angle measurement system composed of multiple single-phase metering chips, including the structure and working principle. It uses the synchronous zero-crossing sampling method to achieve high-precision phase angle measurement, reverse phase sequence analysis and unbalance judgment under three-phase electricity, which has high industrial practical value. Experiments are carried out on the stereotype of the phase angle measurement system. The results have shown that the phase angle runout are all within 0.5°.

Authors

Institutions

Publication Details

Published
2024-11-01
DOI
https://doi.org/10.1109/cac63892.2024.10864479
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phase Angle Measurement System for Energy Meter Composed of Multiple Single-Phase Measuring Chips

Xiaoyu Tang, Q. Chen, Xiaolu Liu, Wenzhong Hu
Engineering Applied Research
article

Phase Angle Measurement System for Energy Meter Composed of Multiple Single-Phase Measuring Chips

Xiaoyu Tang, Q. Chen, Xiaolu Liu, Wenzhong Hu
article en

Abstract

Traditional three-phase electric energy meters adopt the current transformer sampling method, which is susceptible to constant magnetic field interference and easy DC saturation, while the manganese-copper sampling method can well solve the problem of anti-DC component of the electric energy meter. When disturbed by a magnetic field, the energy error jumps, Therefore the all-manganese-copper sampling scheme used on the three-phase electric energy meter mainly faces the problems of electrical isolation of the three-phase metering circuit and the problem of asynchronous sampling of the three-phase signal. This paper introduces a phase angle measurement system composed of multiple single-phase metering chips, including the structure and working principle. It uses the synchronous zero-crossing sampling method to achieve high-precision phase angle measurement, reverse phase sequence analysis and unbalance judgment under three-phase electricity, which has high industrial practical value. Experiments are carried out on the stereotype of the phase angle measurement system. The results have shown that the phase angle runout are all within 0.5°.

Zhejiang University (CN)
Affordable and clean energy
Openalex Percentile: Top 69%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.